Both views use the same certified data. This device remembers your choice.
Carrier vs Trane: heat pump ratings compared
Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Trane model 50%. Trane rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Carrier
49%
of similar heat pumps beaten by its typical model
About average846 models listed
Trane
50%
of similar heat pumps beaten by its typical model
About average369 models listed
- Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Trane: Beats 69%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Trane: Beats 42%
- Winter-long heating efficiencyHSPF2Carrier: Beats 41%Trane: Beats 35%
- Summer-long cooling efficiencySEER2Carrier: Beats 43%Trane: Beats 40%
- Hot-day cooling efficiencyEER2Carrier: Beats 60%Trane: Beats 67%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Carrier
- 42%
- Trane
- 39%
Xcel CC
- Carrier
- 29%
- Trane
- 25%
CEE Advanced
- Carrier
- 1%
- Trane
- 2%
ENERGY STAR CC
- Carrier
- 27%
- Trane
- 17%
Top cold-climate picks, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
Carrier
- 137MGHAQ36EA3Carrier (sold as Bryant)Also sold as Arcoaire D5CMHAH36EAK3 tons · 36,000 Btu/h · DuctedKeeps 106% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 237MBHAQ36AA3with ducted air handler 45MBDAQ36XH3CarrierAlso sold as Arcoaire D5CLHAH36AAK3 tons · 36,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
- 3W5HDM36K1X5ACarrier (sold as Grandaire)3 tons · 36,000 Btu/h · DuctedKeeps 106% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
Trane
- 15TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCBTrane2.5 tons · 29,800 Btu/h · DuctedKeeps 115% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 115% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.85 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
- 25TWV0X36A1with indoor coil 5TEMCD05AV41+TDR and furnace N/ATraneAlso sold as American Standard 5A6V0X36A13 tons · 35,200 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 35A6H7036A1with ducted air handler PL36H175P78*+TXV+TDTrane (sold as American Standard)3 tons · 33,200 Btu/h · DuctedKeeps 132% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 132% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.28 (COP at 5°F)
- Great
- Seasonal efficiency
- 8.2 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view