Century vs DIRECT AIR: heat pump ratings compared

Against heat pumps of the same size and type, a typical Century model beats 50% and a typical DIRECT AIR model 65%. DIRECT AIR rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Century

50%

of similar heat pumps beaten by its typical model

About average

59 models listed

DIRECT AIR

65%

of similar heat pumps beaten by its typical model

Well above average

57 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCentury: Beats 51%DIRECT AIR: Beats 62%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCentury: Beats 49%DIRECT AIR: Beats 63%
  • Winter-long heating efficiencyHSPF2Century: Beats 52%DIRECT AIR: Beats 72%
  • Summer-long cooling efficiencySEER2Century: Beats 45%DIRECT AIR: Beats 69%
  • Hot-day cooling efficiencyEER2Century: Beats 54%DIRECT AIR: Beats 61%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Century
    44%
    DIRECT AIR
    91%
  • Xcel CC

    Century
    41%
    DIRECT AIR
    81%
  • CEE Advanced

    Century
    3%
    DIRECT AIR
    2%
  • ENERGY STAR CC

    Century
    32%
    DIRECT AIR
    79%

All-around best, ducted up to 1.5 tons

Century

  1. 1A-VHP09SA-1with ducted air handler B-VHP09DA-1Century1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    120% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    86.9score / 100Heating 80 · Cooling 94
  2. 2A-ZHP15SA-1with ducted air handler B-ZHP15SA-1Century1.5 tons · 15,000 Btu/h · DuctedCold-climate pick, score 75.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    27.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Great
    84.1score / 100Heating 75 · Cooling 93
  3. 3A-VXP18SA-1with ducted air handler WXP18SACentury1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 86.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.8 (HSPF2)
    Top 10%
    Cooling efficiency
    19.3 (SEER2)
    Good
    Hot-day cooling
    12.1 (EER2)
    Great
    80.3score / 100Heating 87 · Cooling 74

DIRECT AIR

  1. 1DIRM4-09HXPRO28-1Zwith ducted air handler DIRM4-09HP-DUDIRECT AIR1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    120% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    86.9score / 100Heating 80 · Cooling 94
  2. 2DIRM4-09DA25-1Zwith ducted air handler DIRM4-09HP-DUDIRECT AIR1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.32 (COP at 5°F)
    Great
    Winter efficiency
    11.5 (HSPF2)
    Top 10%
    Cooling efficiency
    19.7 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Great
    81.1score / 100Heating 82 · Cooling 81
  3. 3DIRM4-18DA25-1Zwith ducted air handler DIRM4-18HP-DUDIRECT AIR1.5 tons · 17,500 Btu/h · DuctedCold-climate pick, score 70.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.3 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    13.3 (EER2)
    Top 10%
    79.0score / 100Heating 71 · Cooling 87

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter