Both views use the same certified data. This device remembers your choice.
DUCTLESSAIRE vs ISLANDAIRE: heat pump ratings compared
Against heat pumps of the same size and type, a typical DUCTLESSAIRE model beats 56% and a typical ISLANDAIRE model 19%. DUCTLESSAIRE rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
DUCTLESSAIRE
56%
of similar heat pumps beaten by its typical model
Above average16 models listed
ISLANDAIRE
19%
of similar heat pumps beaten by its typical model
Well below average16 models listed
- Efficiency on a 5°F dayCOP at 5°FDUCTLESSAIRE: Beats 64%ISLANDAIRE: Beats 27%
- Heating power kept at 5°FCapacity at 5°F vs 47°FDUCTLESSAIRE: Beats 39%ISLANDAIRE: Beats 18%
- Winter-long heating efficiencyHSPF2DUCTLESSAIRE: Beats 58%ISLANDAIRE: Beats 6%
- Summer-long cooling efficiencySEER2DUCTLESSAIRE: Beats 64%ISLANDAIRE: Beats 22%
- Hot-day cooling efficiencyEER2DUCTLESSAIRE: Beats 52%ISLANDAIRE: Beats 20%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- DUCTLESSAIRE
- 81%
- ISLANDAIRE
- 0%
Xcel CC
- DUCTLESSAIRE
- 75%
- ISLANDAIRE
- 0%
CEE Advanced
- DUCTLESSAIRE
- 0%
- ISLANDAIRE
- 0%
ENERGY STAR CC
- DUCTLESSAIRE
- 63%
- ISLANDAIRE
- 0%
All-around best, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
DUCTLESSAIRE
No ducted, up to 1.5 tons model from DUCTLESSAIRE.
ISLANDAIRE
- 1EZMB10L9A1S95AAISLANDAIREAlso listed as EZMB10L2O1S95AA1 ton · 10,000 Btu/h · DuctedCold-climate pick, score 42.6Meets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 16.4 (SEER2)
- Good
- Hot-day cooling
- 9.9 (EER2)
- Below the middle
- 2EZMB10L5A1S95AAISLANDAIRE1 ton · 10,000 Btu/h · DuctedCold-climate pick, score 31.3Meets none of the standards tracked here
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
- 3EZVV09L2*ISLANDAIREAlso listed as EZVV09L8, EZVV15L2, EZVV15L81 ton · 12,600 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 56% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.61 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.4 (SEER2)
- Below the middle
- Hot-day cooling
- 11.1 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view