Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Friedrich vs Trane: heat pump ratings compared
Against heat pumps of the same size and type, a typical Friedrich model beats 39% and a typical Trane model 50%. Trane rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Friedrich
39%
of similar heat pumps beaten by its typical model
Well below average188 models listed
Trane
50%
of similar heat pumps beaten by its typical model
About average363 models listed
- Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 46%Trane: Beats 68%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 36%Trane: Beats 43%
- Winter-long heating efficiencyHSPF2Friedrich: Beats 31%Trane: Beats 36%
- Summer-long cooling efficiencySEER2Friedrich: Beats 34%Trane: Beats 40%
- Hot-day cooling efficiencyEER2Friedrich: Beats 37%Trane: Beats 66%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Friedrich
- 27%
- Trane
- 39%
Xcel CC
- Friedrich
- 21%
- Trane
- 26%
CEE Advanced
- Friedrich
- 1%
- Trane
- 3%
ENERGY STAR CC
- Friedrich
- 22%
- Trane
- 18%
All-around best, ducted 5 tons and up
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
Friedrich
- 1FRP17AY60AJVCwith ducted air handler RH2TY6024STANNFriedrich5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Good
- 2FRP15AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FWP15AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 50% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 7.8 (HSPF2)
- Good
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3FWP14AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FRP14AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 47% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.8 (HSPF2)
- Good
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
Trane
- 13TXK2260AF00HAATraneAlso listed as 3TVHS060SF000AA5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 81.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 16.8 (SEER2)
- Good
- Hot-day cooling
- 11.5 (EER2)
- Good
- 25WCZ5060A3TraneAlso listed as 5WCZ5060A45 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Good
- 35WCZ5060A1Trane5 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view