Skip to content

Friedrich vs Trane: heat pump ratings compared

Against heat pumps of the same size and type, a typical Friedrich model beats 40% and a typical Trane model 50%. Trane rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Friedrich

40%

of similar heat pumps beaten by its typical model

Well below average

192 models listed

Trane

50%

of similar heat pumps beaten by its typical model

About average

370 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 46%Trane: Beats 69%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 36%Trane: Beats 43%
  • Winter-long heating efficiencyHSPF2Friedrich: Beats 32%Trane: Beats 35%
  • Summer-long cooling efficiencySEER2Friedrich: Beats 35%Trane: Beats 40%
  • Hot-day cooling efficiencyEER2Friedrich: Beats 38%Trane: Beats 67%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Friedrich
    28%
    Trane
    39%
  • Xcel CC

    Friedrich
    22%
    Trane
    25%
  • CEE Advanced

    Friedrich
    1%
    Trane
    2%
  • ENERGY STAR CC

    Friedrich
    22%
    Trane
    17%

All-around best, ducted 5 tons and up

Friedrich

  1. 1FRP17AY60AJVCwith ducted air handler RH2TY6024STANNFriedrich5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    11.0 (EER2)
    Good
    70.6score / 100Heating 78 · Cooling 63
  2. 2FRP15AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FWP15AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    57.0score / 100Heating 56 · Cooling 58
  3. 3FWP14AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FRP14AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    47% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    53.0score / 100Heating 48 · Cooling 58

Trane

  1. 13TXK2260AF00HAATraneAlso listed as 3TVHS060SF000AA5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 81.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    16.8 (SEER2)
    Good
    Hot-day cooling
    11.5 (EER2)
    Good
    74.8score / 100Heating 82 · Cooling 68
  2. 25WCZ5060A1TraneAlso listed as 5WCZ5060A3, 5WCZ5060A45 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    53% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.2 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Good
    50.0score / 100Heating 46 · Cooling 54
  3. 35DCZ5060A1Trane5 tons · 57,500 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.2 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Good
    49.7score / 100Heating 45 · Cooling 54

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter