Fujitsu vs Hisense: heat pump ratings compared

Against heat pumps of the same size and type, a typical Fujitsu model beats 53% and a typical Hisense model 54%. Hisense rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Fujitsu

53%

of similar heat pumps beaten by its typical model

About average

179 models listed

Hisense

54%

of similar heat pumps beaten by its typical model

About average

161 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFujitsu: Beats 60%Hisense: Beats 59%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFujitsu: Beats 48%Hisense: Beats 61%
  • Winter-long heating efficiencyHSPF2Fujitsu: Beats 44%Hisense: Beats 51%
  • Summer-long cooling efficiencySEER2Fujitsu: Beats 43%Hisense: Beats 56%
  • Hot-day cooling efficiencyEER2Fujitsu: Beats 47%Hisense: Beats 46%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Fujitsu
    32%
    Hisense
    80%
  • Xcel CC

    Fujitsu
    30%
    Hisense
    68%
  • CEE Advanced

    Fujitsu
    8%
    Hisense
    8%
  • ENERGY STAR CC

    Fujitsu
    27%
    Hisense
    55%

All-around best, ducted 5 tons and up

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Fujitsu

  1. 1WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAFujitsuAlso listed as FOP1560TJAYNA5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    56.6score / 100Heating 55 · Cooling 58
  2. 2FOP1460TJAYNAwith ducted air handler FHRNVT6024S*YTCAFujitsu5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    49% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    56.2score / 100Heating 54 · Cooling 58
  3. 3WP14AY60AJ2Nwith indoor coil FCCN6024SYTA and furnace FF80SV510021UHSFujitsu5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    45% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    52.2score / 100Heating 46 · Cooling 58

Hisense

  1. 1AUWR-6024Pwith ducted air handler AUH-6024HisenseAlso listed as AOH-60U3T24P5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 88.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.46 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Good
    80.9score / 100Heating 88 · Cooling 73
  2. 2AVW-60F3DAH2Hisense5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 88.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.1 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    70.5score / 100Heating 88 · Cooling 53
  3. 3AR-60U3RBHMHisenseAlso listed as AR-60U3R25U5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 58.3Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.6 (EER2)
    Below the middle
    57.7score / 100Heating 58 · Cooling 57

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.