Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Gree vs Midea: heat pump ratings compared
Against heat pumps of the same size and type, a typical Gree model beats 54% and a typical Midea model 59%. Midea rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Gree
54%
of similar heat pumps beaten by its typical model
About average717 models listed
Midea
59%
of similar heat pumps beaten by its typical model
Above average546 models listed
- Efficiency on a 5°F dayCOP at 5°FGree: Beats 43%Midea: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FGree: Beats 57%Midea: Beats 56%
- Winter-long heating efficiencyHSPF2Gree: Beats 42%Midea: Beats 66%
- Summer-long cooling efficiencySEER2Gree: Beats 60%Midea: Beats 61%
- Hot-day cooling efficiencyEER2Gree: Beats 60%Midea: Beats 54%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Gree
- 81%
- Midea
- 76%
Xcel CC
- Gree
- 80%
- Midea
- 70%
CEE Advanced
- Gree
- 6%
- Midea
- 3%
ENERGY STAR CC
- Gree
- 66%
- Midea
- 64%
All-around best, ducted 3.5–4.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
Gree
- 1MHPC-H-048BMBGree (sold as Ac Pro)4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2A7CP21V48P-**Awith indoor coil 7E[C,U]60CX-**+TDR and furnace A80UH2E110C16Gree (sold as Ac Pro)4 tons · 47,500 Btu/h · DuctedCold-climate pick, score 73.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Winter efficiency
- 9.6 (HSPF2)
- Great
- Cooling efficiency
- 20.5 (SEER2)
- Top 10%
- Hot-day cooling
- 12.2 (EER2)
- Top 10%
- 3GUD48W2/NHE-D(U)with ducted air handler GUD48AH2/E-D(U)GreeAlso sold as Tosot TU48-32WEDU, Tosot TU48W-EDU, Tosot TU60W-EDU, Ac Pro SPHP-X-I060B and 5 more; also listed as FXU48HP230V1R32AO, GUD60W2/NHE-D(U), FXU60HP230V1R32AO, GFU60HP230V1R32AO and 1 more4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 78.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
Midea
- 1D5CMRAH48FAKMideaAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA34 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.5 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2MOVA-60HDN10-M20Gwith ducted air handler MVME48C2MN10TAMideaAlso listed as MOVC-60HDN10-M20G4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 83.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3MO6EX-H48B-2AMideaAlso sold as MDV M6OE30-48HFN10-M1D-D, CTMorley MOU-5B48G-2, CTMorley MOU-6B48G-2; also listed as M6OE30-48HFN10-M1P4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view