Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Kaden vs Mirage: heat pump ratings compared
Against heat pumps of the same size and type, a typical Kaden model beats 61% and a typical Mirage model 48%. Kaden rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Kaden
61%
of similar heat pumps beaten by its typical model
Well above average66 models listed
Mirage
48%
of similar heat pumps beaten by its typical model
About average34 models listed
- Efficiency on a 5°F dayCOP at 5°FKaden: Beats 58%Mirage: Beats 43%
- Heating power kept at 5°FCapacity at 5°F vs 47°FKaden: Beats 53%Mirage: Beats 41%
- Winter-long heating efficiencyHSPF2Kaden: Beats 64%Mirage: Beats 50%
- Summer-long cooling efficiencySEER2Kaden: Beats 63%Mirage: Beats 56%
- Hot-day cooling efficiencyEER2Kaden: Beats 65%Mirage: Beats 37%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Kaden
- 68%
- Mirage
- 77%
Xcel CC
- Kaden
- 59%
- Mirage
- 65%
CEE Advanced
- Kaden
- 3%
- Mirage
- 0%
ENERGY STAR CC
- Kaden
- 58%
- Mirage
- 38%
All-around best, ducted 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
Kaden
- 1KOB-HH-PS436HP-2AAMAKadenAlso listed as KOB-HH-PS536HP-2AAMA3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2KOB-HH-PS327HP-2AAMAKadenAlso listed as KOB-HH-PS427HP-2AAMA2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 72.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3KOB-HH-UUX36HP-2AAMAwith ducted air handler KIB-HH-UUX36AH3-2AAMAKaden3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 77.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 17.7 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Great
Mirage
- 1OGFH351CMirage3 tons · 34,000 Btu/h · DuctedCold-climate pick, score 57.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.5 (SEER2)
- Top 10%
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 2OGFH271CMirage2.5 tons · 27,000 Btu/h · DuctedCold-climate pick, score 45.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.1 (EER2)
- Below the middle
- 3OVADH361Bwith ducted air handler IVADH361BMirage3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 59.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 8.7 (HSPF2)
- Good
- Cooling efficiency
- 16.1 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view