Skip to content

Lennox vs Trane: heat pump ratings compared

Against heat pumps of the same size and type, a typical Lennox model beats 48% and a typical Trane model 50%. Trane rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Lennox

48%

of similar heat pumps beaten by its typical model

About average

341 models listed

Trane

50%

of similar heat pumps beaten by its typical model

About average

370 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLennox: Beats 46%Trane: Beats 69%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLennox: Beats 43%Trane: Beats 43%
  • Winter-long heating efficiencyHSPF2Lennox: Beats 44%Trane: Beats 35%
  • Summer-long cooling efficiencySEER2Lennox: Beats 44%Trane: Beats 40%
  • Hot-day cooling efficiencyEER2Lennox: Beats 57%Trane: Beats 67%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Lennox
    43%
    Trane
    39%
  • Xcel CC

    Lennox
    36%
    Trane
    25%
  • CEE Advanced

    Lennox
    3%
    Trane
    2%
  • ENERGY STAR CC

    Lennox
    29%
    Trane
    17%

All-around best, ducted 5 tons and up

Lennox

  1. 1VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 84.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.04 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    84.7score / 100Heating 84 · Cooling 85
  2. 2SHH060U5E**GLennoxAlso listed as SHH060U5E**J, SDH060U5E**G, SDH060U5E**J5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    7.6 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    11.2 (EER2)
    Good
    67.4score / 100Heating 68 · Cooling 67
  3. 3ML14KP1-060-230A**with ducted air handler CBK45UHVT-060-230-LennoxAlso sold as Allied 7HP14F60P-**A, Armstrong Air A7HP14F60P-**A, Comfort-Aire HSA1460S1-**A; also listed as EL16KP1-060-230A, ML14KP1-060-233A, ML14KP1-060-463A5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 62% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    54% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.24 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    14.7 (SEER2)
    Below the middle
    Hot-day cooling
    12.2 (EER2)
    Top 10%
    67.2score / 100Heating 71 · Cooling 63

Trane

  1. 13TXK2260AF00HAATraneAlso listed as 3TVHS060SF000AA5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 81.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    16.8 (SEER2)
    Good
    Hot-day cooling
    11.5 (EER2)
    Good
    74.8score / 100Heating 82 · Cooling 68
  2. 25WCZ5060A1TraneAlso listed as 5WCZ5060A3, 5WCZ5060A45 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    53% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.2 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Good
    50.0score / 100Heating 46 · Cooling 54
  3. 35DCZ5060A1Trane5 tons · 57,500 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.2 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Good
    49.7score / 100Heating 45 · Cooling 54

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter