Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Midea vs Rheem: heat pump ratings compared
Against heat pumps of the same size and type, a typical Midea model beats 59% and a typical Rheem model 49%. Midea rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Midea
59%
of similar heat pumps beaten by its typical model
Above average546 models listed
Rheem
49%
of similar heat pumps beaten by its typical model
About average341 models listed
- Efficiency on a 5°F dayCOP at 5°FMidea: Beats 59%Rheem: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FMidea: Beats 56%Rheem: Beats 48%
- Winter-long heating efficiencyHSPF2Midea: Beats 66%Rheem: Beats 43%
- Summer-long cooling efficiencySEER2Midea: Beats 61%Rheem: Beats 42%
- Hot-day cooling efficiencyEER2Midea: Beats 54%Rheem: Beats 40%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Midea
- 76%
- Rheem
- 36%
Xcel CC
- Midea
- 70%
- Rheem
- 34%
CEE Advanced
- Midea
- 3%
- Rheem
- 2%
ENERGY STAR CC
- Midea
- 64%
- Rheem
- 33%
All-around best, ducted 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling). What size is my system?
Midea
- 1D5CMHAH30EAKMideaAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA32.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 78.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 116% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.95 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.5 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 2D5CMHAH36EAKMideaAlso sold as MDV M5OX631-36HFN10-M1XD, MDV M5OX631-36HFN10-M1X; also listed as 37MGHAQ36EA33 tons · 36,000 Btu/h · DuctedCold-climate pick, score 83.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.5 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3MOU-4B36H-2Midea (sold as CTMorley)3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 83.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
Rheem
- 1RD18AY36AJVCwith ducted air handler L(E,G)M36FJRheem2.5 tons · 30,800 Btu/h · DuctedCold-climate pick, score 94.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 109% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.86 (COP at 5°F)
- Top 10%
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2ML36HP230MULH-ORheem (sold as Mainline)Also listed as ML36HP230MULH-O3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3RP19AY36AJVCwith indoor coil RCFY3621MEAAM and furnace R97MV0603A17DHRheemAlso sold as RUUD UP19AY36AJVC, SURE SP19AY36AJVC3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 70.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view