Skip to content

Midea vs Trane: heat pump ratings compared

Against heat pumps of the same size and type, a typical Midea model beats 60% and a typical Trane model 50%. Midea rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Midea

60%

of similar heat pumps beaten by its typical model

Above average

555 models listed

Trane

50%

of similar heat pumps beaten by its typical model

About average

370 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FMidea: Beats 60%Trane: Beats 69%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FMidea: Beats 57%Trane: Beats 43%
  • Winter-long heating efficiencyHSPF2Midea: Beats 66%Trane: Beats 35%
  • Summer-long cooling efficiencySEER2Midea: Beats 61%Trane: Beats 40%
  • Hot-day cooling efficiencyEER2Midea: Beats 55%Trane: Beats 67%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Midea
    75%
    Trane
    39%
  • Xcel CC

    Midea
    70%
    Trane
    25%
  • CEE Advanced

    Midea
    3%
    Trane
    2%
  • ENERGY STAR CC

    Midea
    64%
    Trane
    17%

All-around best, ducted up to 1.5 tons

Midea

  1. 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3MideaAlso sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    21.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.5 (EER2)
    Top 10%
    95.7score / 100Heating 94 · Cooling 98
  2. 2MO1HS-H06B-2Awith ducted air handler MDLHU-H06B-2AMidea0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    21.4 (SEER2)
    Top 10%
    Hot-day cooling
    14.4 (EER2)
    Top 10%
    95.1score / 100Heating 94 · Cooling 97
  3. 3M3OD31-18HFN8-M1XDMidea (sold as MDV)1.5 tons · 19,000 Btu/h · DuctedCold-climate pick, score 86.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.08 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    22.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.5 (EER2)
    Top 10%
    92.5score / 100Heating 87 · Cooling 98

Trane

  1. 15TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRPTrane1.5 tons · 20,000 Btu/h · DuctedCold-climate pick, score 92.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    120% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.95 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    22.2 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    85.1score / 100Heating 92 · Cooling 78
  2. 2NONLIST-18K-HP-W-Twith ducted air handler NONLIST-18K-HP-I-TTrane1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 72.5Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    16.8 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    67.9score / 100Heating 73 · Cooling 63
  3. 35TWX5024A1with indoor coil DH36T4J and furnace L9X1A050U3VSATrane1.5 tons · 20,800 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    69% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.51 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    55.2score / 100Heating 47 · Cooling 63

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter