Skip to content

Midea vs Trane heat pumps

Measured against models of the same size and duct type, Midea scores higher on 4 of the 6 ratings. Midea has 546 outdoor models, Trane has 363 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Midea and Trane on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Midea scores higher on 4 of the 6 ratings.
  • Midea
  • Trane
  • Other ranked manufacturers
MideaTrane

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMideaTrane
Efficiency index59% (higher)median — · 7th ranked50% (higher)median — · 19th ranked
COP at 5°F59%median 2.00 · 9th ranked68%median 2.24 · 1st ranked
Capacity retention at 5°F56% (higher)median 74% · 11th ranked43% (higher)median 65% · 24th ranked
HSPF266% (higher)median 9.5 · 7th ranked36% (higher)median 7.5 · 27th ranked
SEER261% (higher)median 19.5 · 6th ranked40% (higher)median 15.5 · 25th ranked
EER254%median 11.7 · 15th ranked66%median 11.7 · 3rd ranked
Heating capacity at 5°F59% (higher)median 20,400 Btu/h · 10th ranked44% (higher)median 21,800 Btu/h · 24th ranked
Outdoor models546363
AHRI certifications5,35684,774

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMideaTrane
CEE 2025 Tier 1 (Split ASHP)75.5%412 models38.6%140 models
CEE 2026 Tier 1 (Split ASHP)73.8%403 models36.6%133 models
CEE Advanced Tier (Split ASHP)3.1%17 models2.5%9 models
Xcel Energy Colorado cold-climate ASHP (2025)69.8%381 models25.6%93 models
DOE Cold Climate Heat Pump Challenge3.1%17 models2.5%9 models
ENERGY STAR Cold Climate63.9%349 models17.9%65 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Midea
  • Trane
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMideaTrane
Ducted, up to 1.5 tons79 · index 73%18 · index 46%
Ducted, 2 tons57 · index 62%42 · index 44%
Ducted, 2.5–3 tons121 · index 61%102 · index 49%
Ducted, 3.5–4.5 tons109 · index 63%131 · index 53%
Ducted, 5 tons and up22 · index 63%46 · index 49%
Non-ducted, up to 1.5 tons179 · index 55%15 · index 53%
Non-ducted, 2 tons50 · index 51%4 · index 42%
Non-ducted, 2.5–3 tons92 · index 55%7 · index 56%
Non-ducted, 3.5–4.5 tons64 · index 50%3 · index 63%
Non-ducted, 5 tons and up15 · index 44%2 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMideaCold-climate score, best modelTraneCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK70 of 80 models qualify · AHRI 21532404292.5(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB5 of 20 models qualify · AHRI 216794262
Ducted, 2 tons86.4(50 is the typical model of its size class)MOU-B24H-2with ducted air handler MIU-B24D-249 of 54 models qualify · AHRI 21702211090.0(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A115 of 40 models qualify · AHRI 218792275
Ducted, 2.5–3 tons88.8(50 is the typical model of its size class) (higher)MOE30-36HFN10-M3Xwith ducted air handler MVBDM-36HWFN10-WC391 of 125 models qualify · AHRI 21696794784.6(50 is the typical model of its size class)5TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCB24 of 102 models qualify · AHRI 216797087
Ducted, 3.5–4.5 tons83.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 21481447793.0(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP38 of 131 models qualify · AHRI 216794596
Ducted, 5 tons and up65.9(50 is the typical model of its size class)MDV-V60WMN10T5 of 23 models qualify · AHRI 21602106281.1(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025
Non-ducted, up to 1.5 tons97.5(50 is the typical model of its size class) (higher)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1121 of 179 models qualify · AHRI 21586589068.6(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 21532405937.7(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437
Non-ducted, 2.5–3 tons89.8(50 is the typical model of its size class) (higher)MOU-B36LH-2with ductless indoor unit MIU-B36LF-276 of 92 models qualify · AHRI 21702211473.8(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026
Non-ducted, 3.5–4.5 tons75.5(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 21535741767.2(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027
Non-ducted, 5 tons and up50.6(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 21602108164.1(50 is the typical model of its size class) (higher)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMideaAll-around score, best modelTraneAll-around score, best model
Ducted, up to 1.5 tons95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK80 of 80 models have all five ratings · AHRI 21532404284.4(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP17 of 17 models have all five ratings · AHRI 216794699
Ducted, 2 tons89.9(50 is the typical model of its size class) (higher)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H57 of 57 models have all five ratings · AHRI 21799829386.7(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A131 of 31 models have all five ratings · AHRI 218792275
Ducted, 2.5–3 tons85.5(50 is the typical model of its size class)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA3120 of 120 models have all five ratings · AHRI 21535741088.5(50 is the typical model of its size class) (higher)5TWV0X36A1with indoor coil 5PX*D010AS3 and furnace S8V2D120M5PDBAlso sold as American Standard 5A6V0X36A171 of 107 models have all five ratings · AHRI 216453109
Ducted, 3.5–4.5 tons85.7(50 is the typical model of its size class)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3109 of 109 models have all five ratings · AHRI 21535744588.9(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP102 of 138 models have all five ratings · AHRI 216794476
Ducted, 5 tons and up70.1(50 is the typical model of its size class)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 21589425074.7(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025
Non-ducted, up to 1.5 tons96.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK170 of 179 models have all five ratings · AHRI 21532378672.2(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 21532379648.8(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437
Non-ducted, 2.5–3 tons85.8(50 is the typical model of its size class) (higher)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA391 of 92 models have all five ratings · AHRI 21535740976.2(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026
Non-ducted, 3.5–4.5 tons76.7(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 21535741573.9(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027
Non-ducted, 5 tons and up61.3(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 21535745067.9(50 is the typical model of its size class) (higher)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMideaTrane
COP at 5°Fbeats 99% · 2.5137MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAKNon-ducted, up to 1.5 tonsbeats 100% · 3.205TWR4036A1Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tonsbeats 100% · 136%5A6H7036A1Ducted, 2.5–3 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tonsbeats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5–3 tons
SEER2beats 100% · 27.0MOX430-15HFN10-M1HDucted, up to 1.5 tonsbeats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5–3 tons
EER2beats 100% · 18.1MOX230-06HFN10-M1Non-ducted, up to 1.5 tonsbeats 99% · 14.43TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAANon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 100% · 55,000 Btu/hMOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20GDucted, 3.5–4.5 tonsbeats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons

More comparisons