Both views use the same certified data. This device remembers your choice.
Nutech vs Pioneer: heat pump ratings compared
Against heat pumps of the same size and type, a typical Nutech model beats 54% and a typical Pioneer model 48%. Nutech rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Nutech
54%
of similar heat pumps beaten by its typical model
About average50 models listed
Pioneer
48%
of similar heat pumps beaten by its typical model
About average46 models listed
- Efficiency on a 5°F dayCOP at 5°FNutech: Beats 57%Pioneer: Beats 42%
- Heating power kept at 5°FCapacity at 5°F vs 47°FNutech: Beats 45%Pioneer: Beats 44%
- Winter-long heating efficiencyHSPF2Nutech: Beats 57%Pioneer: Beats 58%
- Summer-long cooling efficiencySEER2Nutech: Beats 69%Pioneer: Beats 57%
- Hot-day cooling efficiencyEER2Nutech: Beats 41%Pioneer: Beats 40%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Nutech
- 70%
- Pioneer
- 74%
Xcel CC
- Nutech
- 48%
- Pioneer
- 70%
CEE Advanced
- Nutech
- 0%
- Pioneer
- 0%
ENERGY STAR CC
- Nutech
- 0%
- Pioneer
- 54%
All-around best, ductless 2 tons
Showing Ductless, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
Nutech
- 1N4OD30-27HFN10-M1D-DNutech2 tons · 26,000 Btu/h · DuctlessCold-climate pick, score 43.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 12.2 (EER2)
- Good
- 2NOX430-24HFN10-230with ductless indoor unit NSAG11D-24HRFN10-230Nutech2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 47.2Meets Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.11 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.5 (SEER2)
- Below the middle
- Hot-day cooling
- 9.6 (EER2)
- Below the middle
Pioneer
- 1YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHGPioneer2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 60.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.4 (HSPF2)
- Great
- Cooling efficiency
- 22.5 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 2YN024GLSI25RPHwith ductless indoor unit WT024GLSI25HLHPioneer2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 59.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 22.5 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3YN024GLSI20RPFwith ductless indoor unit WT024GLSI20HLFPioneer2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 68% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 68% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.0 (SEER2)
- Good
- Hot-day cooling
- 10.5 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view