Nutech vs Pioneer heat pumps

Measured against models of the same size and duct type, Nutech scores higher on 5 of the 6 ratings. Nutech has 50 outdoor models, Pioneer has 46 outdoor models. Nutech has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Nutech and Pioneer on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Nutech scores higher on 5 of the 6 ratings.
  • Nutech
  • Pioneer
  • Other ranked manufacturers
NutechPioneer

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingNutechPioneer
Efficiency index54% (higher)median —48% (higher)median — · 24th ranked
COP at 5°F57% (higher)median 2.0042% (higher)median 1.88 · 27th ranked
Capacity retention at 5°F45% (higher)median 68%44% (higher)median 73% · 22nd ranked
HSPF257%median 8.858%median 9.5 · 10th ranked
SEER269% (higher)median 18.857% (higher)median 20.0 · 11th ranked
EER241% (higher)median 10.940% (higher)median 11.2 · 25th ranked
Heating capacity at 5°F51% (higher)median 22,000 Btu/h46% (higher)median 12,800 Btu/h · 22nd ranked
Outdoor models5046
AHRI certifications6669

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardNutechPioneer
CEE 2025 Tier 1 (Split ASHP)70%35 models73.9%34 models
CEE 2026 Tier 1 (Split ASHP)66%33 models73.9%34 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)48%24 models69.6%32 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models54.3%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Nutech
  • Pioneer
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeNutechPioneer
Ducted, up to 1.5 tons6 · index 66%4 · index 55%
Ducted, 2 tons8 · index 66%2 · index 68%
Ducted, 2.5 to 3 tons10 · index 51%4 · index 56%
Ducted, 3.5 to 4.5 tons16 · index 52%4 · index 59%
Ducted, 5 tons and up2 · index 65%1 · index 71%
Non-ducted, up to 1.5 tons6 · index 43%26 · index 50%
Non-ducted, 2 tons2 · index 45%5 · index 38%
Non-ducted, 2.5 to 3 tons3 · index 43%8 · index 32%
Non-ducted, 3.5 to 4.5 tons1 · index 51%3 · index 38%
Non-ducted, 5 tons and up1 · index 27%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeNutechCold-climate score, best modelPioneerCold-climate score, best model
Ducted, up to 1.5 tons81.7(50 is the typical model of its size class) (higher)NOX230-09HFN10-M1with ducted air handler NTJ-09HWFN10-M1-D4 of 6 models qualify · AHRI 21657894259.4(50 is the typical model of its size class)YN009GLSI24RPG4 of 4 models qualify · AHRI 217048762
Ducted, 2 tons77.1(50 is the typical model of its size class) (higher)NOD30-24HFN10-M1with ducted air handler NTJ-24HWFN10-M1-D7 of 8 models qualify · AHRI 21589426766.8(50 is the typical model of its size class)YD2436GCSI18RDwith ducted air handler DC024GCSICDHRT2 of 2 models qualify · AHRI 217048497
Ducted, 2.5 to 3 tons60.4(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D3 of 10 models qualify · AHRI 21589427862.1(50 is the typical model of its size class) (higher)YN040GLSI24M4G2 of 4 models qualify · AHRI 217048774
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class) (higher)N6OE30-48HFN10-M1D-D8 of 16 models qualify · AHRI 21589428167.8(50 is the typical model of its size class)YN048GMSI20RUGwith ducted air handler RB048GMSILDFHG4 of 4 models qualify · AHRI 218010994
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)64.2(50 is the typical model of its size class)PRD-60HWD1N10-M18G1 of 1 models qualify · AHRI 216684003
Non-ducted, up to 1.5 tons67.5(50 is the typical model of its size class)N3OX430-18HFN10-M1-D3 of 6 models qualify · AHRI 21589427379.7(50 is the typical model of its size class) (higher)YN018GMSI24RPGwith ductless indoor unit FB018GMSILDFHG21 of 26 models qualify · AHRI 218010990
Non-ducted, 2 tons47.2(50 is the typical model of its size class)NOX430-24HFN10-230with ductless indoor unit NSAG11D-24HRFN10-2302 of 2 models qualify · AHRI 21589426260.1(50 is the typical model of its size class) (higher)YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHG2 of 5 models qualify · AHRI 217048761
Non-ducted, 2.5 to 3 tons48.2(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D1 of 3 models qualify · AHRI 21589427763.6(50 is the typical model of its size class) (higher)YN036GMSI20RUGwith ductless indoor unit CB036GMSILDFHG3 of 8 models qualify · AHRI 218010991
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class) (higher)N6OE30-48HFN10-M1D-D1 of 1 models qualify · AHRI 21589428255.8(50 is the typical model of its size class)YN048GMSI20RUGwith ductless indoor unit CB048GMSILDFHG3 of 3 models qualify · AHRI 218010992
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeNutechAll-around score, best modelPioneerAll-around score, best model
Ducted, up to 1.5 tons81.3(50 is the typical model of its size class) (higher)NOX230-09HFN10-M1with ducted air handler NTJ-09HWFN10-M1-D6 of 6 models have all five ratings · AHRI 21657894265.8(50 is the typical model of its size class)YN009GLSI24RPG4 of 4 models have all five ratings · AHRI 217048762
Ducted, 2 tons78.9(50 is the typical model of its size class)NOD30-24HFN10-M1with ducted air handler NTJ-24HWFN10-M1-D8 of 8 models have all five ratings · AHRI 21589426779.5(50 is the typical model of its size class) (higher)YD2436GCSI18RDwith ducted air handler DC024GCSICDHRT2 of 2 models have all five ratings · AHRI 217048497
Ducted, 2.5 to 3 tons70.0(50 is the typical model of its size class) (higher)N5OD30-36HFN10-M1D-D10 of 10 models have all five ratings · AHRI 21589427864.1(50 is the typical model of its size class)YN040GLSI24M4G4 of 4 models have all five ratings · AHRI 217048774
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)N6OE30-48HFN10-M1D-D16 of 16 models have all five ratings · AHRI 21589428165.3(50 is the typical model of its size class)YD4860GCSI18RDwith ducted air handler DC048GCSICDHRT4 of 4 models have all five ratings · AHRI 217048499
Ducted, 5 tons and up65.9(50 is the typical model of its size class)NOE30-60HFN10-M2with ducted air handler NHJ-60HWFN10-M2-D2 of 2 models have all five ratings · AHRI 21589427070.5(50 is the typical model of its size class) (higher)PRD-60HWD1N10-M18G1 of 1 models have all five ratings · AHRI 216684003
Non-ducted, up to 1.5 tons64.2(50 is the typical model of its size class)N3OX430-18HFN10-M1-D6 of 6 models have all five ratings · AHRI 21589427177.5(50 is the typical model of its size class) (higher)YN012GMSI24RPGwith ductless indoor unit FB012GMSILDFHG26 of 26 models have all five ratings · AHRI 218010989
Non-ducted, 2 tons59.0(50 is the typical model of its size class) (higher)N4OD30-27HFN10-M1D-D2 of 2 models have all five ratings · AHRI 21589427458.9(50 is the typical model of its size class)YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHG5 of 5 models have all five ratings · AHRI 217048761
Non-ducted, 2.5 to 3 tons59.3(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D3 of 3 models have all five ratings · AHRI 21589427765.9(50 is the typical model of its size class) (higher)YN030GLSI24M3G8 of 8 models have all five ratings · AHRI 217048769
Non-ducted, 3.5 to 4.5 tons53.1(50 is the typical model of its size class) (higher)N6OE30-48HFN10-M1D-D1 of 1 models have all five ratings · AHRI 21589428242.3(50 is the typical model of its size class)YN050GLSI24M5G3 of 3 models have all five ratings · AHRI 217048771
Non-ducted, 5 tons and up32.9(50 is the typical model of its size class)N6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 215894283No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingNutechPioneer
COP at 5°Fbeats 95% · 2.44NOX230-12HFN10-M1Ducted, up to 1.5 tonsbeats 99% · 2.51YN012GMSI24RPGNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 103%NWDA-24HIN4-M-SE18Ducted, 2 tonsbeats 93% · 106%YN009GLSI25RPHNon-ducted, up to 1.5 tons
HSPF2beats 95% · 11.5NOX230-09HFN10-M1Ducted, up to 1.5 tonsbeats 97% · 13.5YN018GMSI24RPGNon-ducted, up to 1.5 tons
SEER2beats 96% · 20.4N6OE30-48HFN10-M1D-DDucted, 3.5 to 4.5 tonsbeats 98% · 21.0YN030GLSI24M3GDucted, 2.5 to 3 tons
EER2beats 91% · 13.3NOX430-18HFN10-M1Ducted, up to 1.5 tonsbeats 93% · 13.3YD2436GCSI18RDDucted, 2 tons
Heating capacity at 5°Fbeats 97% · 25,800 Btu/hNWDA-24HIN4-M-SE18Ducted, 2 tonsbeats 91% · 17,800 Btu/hYN018GLSI25RPHNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Nutech vs Pioneer: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Nutech (median, middle 50%)
  • Pioneer (median, middle 50%)
Heating capacity, % of its 47°F maximum62%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Nutech: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F26100%100%100%100%100%
Nutech, 17°F2662%66%69%72%77%
Nutech, 5°F2656%59%62%65%68%
Nutech: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F262.933.13.323.523.8
Nutech, 17°F262.172.242.352.522.6
Nutech, 5°F261.851.9622.112.31
Pioneer: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F33100%100%100%100%100%
Pioneer, 17°F3366%69%73%76%83%
Pioneer, 5°F3357%60%66%70%73%
Pioneer: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F332.843.143.333.513.66
Pioneer, 17°F332.042.12.22.272.49
Pioneer, 5°F331.81.8422.12.16

Source: NEEP ccASHP list · as of