Skip to content

OUTES vs TRUENORTH: heat pump ratings compared

Against heat pumps of the same size and type, a typical OUTES model beats 56% and a typical TRUENORTH model 58%. TRUENORTH rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

OUTES

56%

of similar heat pumps beaten by its typical model

Above average

24 models listed

TRUENORTH

58%

of similar heat pumps beaten by its typical model

Above average

24 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FOUTES: Beats 60%TRUENORTH: Beats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FOUTES: Beats 50%TRUENORTH: Beats 70%
  • Winter-long heating efficiencyHSPF2OUTES: Beats 36%TRUENORTH: Beats 55%
  • Summer-long cooling efficiencySEER2OUTES: Beats 34%TRUENORTH: Beats 58%
  • Hot-day cooling efficiencyEER2OUTES: Beats 52%TRUENORTH: Beats 58%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    OUTES
    25%
    TRUENORTH
    96%
  • Xcel CC

    OUTES
    25%
    TRUENORTH
    96%
  • CEE Advanced

    OUTES
    0%
    TRUENORTH
    13%
  • ENERGY STAR CC

    OUTES
    25%
    TRUENORTH
    79%

All-around best, ducted 2 tons

OUTES

  1. 1OTD-H36DMR3-B01/SE180with ducted air handler OAH-C24DMR3-A01/SE180OUTES2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 67.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    79% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.15 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    13.2 (EER2)
    Top 10%
    76.5score / 100Heating 68 · Cooling 85
  2. 2ORT-H24DEMR3-M01/SE180OUTES2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 68.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.3 (EER2)
    Great
    73.3score / 100Heating 68 · Cooling 78
  3. 3OTD-H24SMR6-A01/SE150with ducted air handler 26UCS(*,E,Q,R,W)*XOUTES2 tons · 22,000 Btu/h · DuctedNot a cold-climate pick: keeps 45% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    45% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.2 (EER2)
    Below the middle
    26.2score / 100Heating 28 · Cooling 25

TRUENORTH

  1. 1GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)TRUENORTHAlso listed as WLUD24W2/NHE-D(U)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 76.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    68.6score / 100Heating 76 · Cooling 61
  2. 2GUD36W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)TRUENORTHAlso listed as WLUD36W2/NHE-D(U)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 74.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    67.9score / 100Heating 75 · Cooling 61
  3. 3WLWHD(24)ND6MOTRUENORTH2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 48.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    54.9score / 100Heating 49 · Cooling 61

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter