Both views use the same certified data. This device remembers your choice.
Senville vs VKIN: heat pump ratings compared
Against heat pumps of the same size and type, a typical Senville model beats 65% and a typical VKIN model 60%. Senville rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Senville
65%
of similar heat pumps beaten by its typical model
Well above average34 models listed
VKIN
60%
of similar heat pumps beaten by its typical model
Above average33 models listed
- Efficiency on a 5°F dayCOP at 5°FSenville: Beats 57%VKIN: Beats 53%
- Heating power kept at 5°FCapacity at 5°F vs 47°FSenville: Beats 69%VKIN: Beats 57%
- Winter-long heating efficiencyHSPF2Senville: Beats 73%VKIN: Beats 62%
- Summer-long cooling efficiencySEER2Senville: Beats 69%VKIN: Beats 72%
- Hot-day cooling efficiencyEER2Senville: Beats 62%VKIN: Beats 51%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Senville
- 82%
- VKIN
- 94%
Xcel CC
- Senville
- 74%
- VKIN
- 91%
CEE Advanced
- Senville
- 3%
- VKIN
- 3%
ENERGY STAR CC
- Senville
- 71%
- VKIN
- 70%
All-around best, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Senville
- 1SENA-48HF-MOASenville4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 2SENA-55HF-MOASenville4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 3SENDC-48HF-OGwith ducted air handler SENDC-48HF-IGSenville4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 68.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 16.5 (SEER2)
- Good
- Hot-day cooling
- 10.5 (EER2)
- Below the middle
VKIN
- 1UCHA-48HDCTwith ducted air handler UCHA-48HDCVKIN4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 73.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Great
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 2UCHA-48HDCSN4with ducted air handler UCHA-48HDCN4VKIN4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 76.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Great
- Cooling efficiency
- 17.5 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 3URHT-42FM5N4VKIN3.5 tons · 41,000 Btu/h · DuctedCold-climate pick, score 55.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 19.5 (SEER2)
- Great
- Hot-day cooling
- 11.1 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view