Skip to content

CEE 2025: which heat pumps meet it?

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 49% of certified models (4,801, about 5 in 10) meet it.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons2,244 of 3,201 models70%
  • 2 tons832 of 1,454 models57%
  • 2.5 to 3 tons1,109 of 2,633 models42%
  • 3.5 to 4.5 tons557 of 2,174 models26%
  • 5 tons and up59 of 362 models16%

All sizes: 49%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1ARUN024GSS4LG2 tons · 24,000 Btu/h · DuctlessTop 10%3.59
  2. 24HP18V36Pwith indoor coil C(A,C,D,E)36B34+TDR and furnace 80G1UH070AE12Lennox (sold as Ducane)2 tons · 22,400 Btu/h · DuctedTop 10%3.19
  3. 34SHP18LX136Pwith indoor coil D(A,C,E)36A34+TDR and furnace A97USMV070B12Lennox (sold as Armstrong Air)2 tons · 21,800 Btu/h · DuctedTop 10%3.15
  4. 4RP15AZ24AJ2Nwith indoor coil D(A,C,E)36D24+TDR and furnace R801V1004A17UHNRheem2 tons · 22,200 Btu/h · DuctedTop 10%3.15
  5. 538MURAQ24AB3*with indoor coil D(A,C,E)36B34+TDR and furnace PG96MSAA48060BCarrier (sold as Payne Heating and Cooling)2 tons · 23,600 Btu/h · DuctedTop 10%3.09
  6. 6WP15AZ24AJ2Nwith ducted air handler CM24C24+TDRRheem (sold as Weatherking)2 tons · 21,200 Btu/h · DuctedTop 10%3.04
  7. 7DLCURAH24ABKwith indoor coil D(A,C,E)30C44+TDR and furnace *92ESN0802120ACarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%3.03
  8. 8T4H7T24*K*AAA*with indoor coil D(A,C,E)30C44+TDR and furnace *80CTL0901716ACarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%3.03
  9. 925TPA724A**30*with indoor coil D(A,C,E)30C44+TDR and furnace 58TP*B135V24**22Carrier2 tons · 23,000 Btu/h · DuctedTop 10%3.02
  10. 10YZT24B21with ducted air handler AE(D,N,U)+CM36B34+TDRYork2 tons · 21,600 Btu/h · DuctedTop 10%3.01

544 ducted, 2 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 49%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter