Skip to content

CEE 2025: which heat pumps meet it?

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 57% of certified models (7,790, about 6 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,352 of 5,427 models62%
  • 2 tons1,308 of 1,941 models67%
  • 2.5 to 3 tons1,685 of 2,942 models57%
  • 3.5 to 4.5 tons1,293 of 2,834 models46%
  • 5 tons and up152 of 475 models32%

All sizes: 57%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1UPC24CN23STG1with ducted air handler JHE24B5AC2SS1York (sold as Guardian)2 tons · 24,000 Btu/h · DuctedTop 10%3.55
  2. 2KUSXA301Awith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons · 21,400 Btu/h · DuctedTop 10%3.43
  3. 337MURAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 23,400 Btu/h · DuctedTop 10%3.16
  4. 4NS18H24HA5***with ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons · 22,400 Btu/h · DuctedTop 10%3.13
  5. 537MUHAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 22,000 Btu/h · DuctedTop 10%3.06
  6. 6AOUK024SSAN7Fujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%3.03
  7. 7KUSXB301Awith ducted air handler D(A,C,E)31D3D+TDRLG2 tons · 26,000 Btu/h · DuctedTop 10%3.00
  8. 8248TAN024**AA*with indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier (sold as Bryant Heating and Cooling Systems)2 tons · 23,000 Btu/h · DuctedTop 10%2.90
  9. 9D5CUHAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
  10. 10D5CURAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88

801 ducted, 2 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 57%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy