- Insights
- Rebate standards
- CEE 2025
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025: which heat pumps meet it?
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 57% of certified models (7,034, about 6 in 10) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,928 of 4,712 models62%
- 2 tons1,181 of 1,747 models68%
- 2.5–3 tons1,558 of 2,722 models57%
- 3.5–4.5 tons1,222 of 2,687 models45%
- 5 tons and up145 of 458 models32%
All sizes: 57%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
- 1UPC24CN23STG1with ducted air handler JHE24B5AC2SS1York (sold as Guardian)2 tons · 24,000 Btu/h · DuctedTop 10%3.55
- 2KUSXA301Awith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons · 21,400 Btu/h · DuctedTop 10%3.43
- 337MURAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 23,400 Btu/h · DuctedTop 10%3.16
- 4NS18H24HA5***with ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons · 22,400 Btu/h · DuctedTop 10%3.13
- 537MUHAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 22,000 Btu/h · DuctedTop 10%3.06
- 6AOUK024SSAN7Fujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%3.03
- 7KUSXB301Awith ducted air handler D(A,C,E)31D3D+TDRLG2 tons · 26,000 Btu/h · DuctedTop 10%3.00
- 8248TAN024**AA*with indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier (sold as Bryant Heating and Cooling Systems)2 tons · 23,000 Btu/h · DuctedTop 10%2.90
- 9D5CUHAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
- 10D5CURAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
751 ducted, 2 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view