- Insights
- Rebate standards
- CEE 2025
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025: which heat pumps meet it?
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 57% of certified models (7,034, about 6 in 10) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,928 of 4,712 models62%
- 2 tons1,181 of 1,747 models68%
- 2.5–3 tons1,558 of 2,722 models57%
- 3.5–4.5 tons1,222 of 2,687 models45%
- 5 tons and up145 of 458 models32%
All sizes: 57%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
- 137MUHAQ18AA3with indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons · 17,200 Btu/h · DuctedTop 10%3.30
- 2HH824E2S11with indoor coil D(A,C,E)37E2J+TDR and furnace Y82E080B12LMPS1York1.5 tons · 20,600 Btu/h · DuctedTop 10%3.20
- 337MUHAQ18AA3+TIC2025-0016with ducted air handler L(E,G)M36DJCarrier1.5 tons · 18,000 Btu/h · DuctedTop 10%3.18
- 4KUSXB181Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 16,800 Btu/h · DuctedTop 10%3.17
- 5KUSXA181Awith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons · 16,900 Btu/h · DuctedTop 10%3.01
- 6SUZ-AA09NL***with ducted air handler PEAD-AA09NLMitsubishi Electric1 ton · 9,000 Btu/h · DuctedTop 10%3.00
- 75TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons · 19,800 Btu/h · DuctedTop 10%2.99
- 8KUSXB241Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 20,400 Btu/h · DuctedTop 10%2.95
- 9ACIQ-18-HPDwith ducted air handler CM24A2J+TDRACIQ1.5 tons · 16,100 Btu/h · DuctedTop 10%2.93
- 10SUZ-AA18NL***with ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons · 18,000 Btu/h · DuctedTop 10%2.93
894 ducted, up to 1.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view