- Insights
- Rebate standards
- CEE 2025
Both views use the same certified data. This device remembers your choice.
CEE 2025: which heat pumps meet it?
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 49% of certified models (4,801, about 5 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,244 of 3,201 models70%
- 2 tons832 of 1,454 models57%
- 2.5 to 3 tons1,109 of 2,633 models42%
- 3.5 to 4.5 tons557 of 2,174 models26%
- 5 tons and up59 of 362 models16%
All sizes: 49%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ductless, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
- 1MCY-MAP0367HS-ULCarrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctedTop 10%3.05
- 2PUZ-A30NHA7***with ductless indoor unit PLA-A30EAMitsubishi Electric2.5 tons · 30,000 Btu/h · DuctlessTop 10%2.90
- 3TRUZA0301HA70**with ductless indoor unit PLA-A30EAMitsubishi Electric (sold as Trane / Mitsubishi Electric)2.5 tons · 30,000 Btu/h · DuctlessTop 10%2.90
- 4MCY-MAP0367HS-UL*Carrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctlessTop 10%2.70
- 5MCY-MAP0367HS-UL*Carrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctlessTop 10%2.70
- 6LMU303HVLG2.5 tons · 28,600 Btu/h · DuctlessTop 10%2.57
- 7LMU303HVLG2.5 tons · 28,600 Btu/h · DuctlessTop 10%2.57
- 8RAV-SP302AT2P-ULwith ductless indoor unit RAV-SM302UTP-ULCarrier (sold as Toshiba Carrier)2.5 tons · 30,000 Btu/h · DuctlessTop 10%2.50
- 9RXSQ36TBVJU*Daikin3 tons · 34,200 Btu/h · DuctlessTop 10%2.50
- 10RXSQ36TBVJU*Daikin3 tons · 34,200 Btu/h · DuctlessTop 10%2.50
1,155 ductless, 2.5 to 3 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.
Open the advanced view