Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DOE CCHP: which heat pumps meet it?
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge. 2.6% of certified models (322, about 1 in 40) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Challenge specification
- Efficiency on a 5°F day (COP at 5°F): 2.1 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 100% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
A model counts when at least one of its certified pairings meets every line on its own. Requirements not published in AHRI ratings (cut-in temperature, GWP, controls) are not checked. Source: U.S. Department of Energy
- Up to 1.5 tons171 of 4,712 models4%
- 2 tons38 of 1,747 models2%
- 2.5–3 tons58 of 2,722 models2%
- 3.5–4.5 tons53 of 2,687 models2%
- 5 tons and up2 of 458 models0%
All sizes: 2.6%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
- 1SL22KLV-060-230A**with indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons · 52,500 Btu/h · DuctedTop 10%3.09
- 2HH860E2S11with ducted air handler L(E,G)M48HJYork4 tons · 46,500 Btu/h · DuctedTop 10%2.90
- 35TWV8X48A1with indoor coil D(A,C,E)48C3J+TDR and furnace S8V2C080M5PCBTrane4 tons · 45,000 Btu/h · DuctedTop 10%2.89
- 45TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRPTrane3.5 tons · 41,500 Btu/h · DuctedTop 10%2.81
- 5H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120ACarrier (sold as HEIL)3.5 tons · 43,000 Btu/h · DuctedTop 10%2.70
- 6NS18H60HA5***with ducted air handler L(E,G)M48EJGE Appliances4 tons · 45,000 Btu/h · DuctedTop 10%2.63
- 7NS21H48MA5-**Awith indoor coil D(A,C,E)48D4Z+TXV+TDR and furnace NF80U110S5CGE Appliances (sold as GE)3.5 tons · 44,500 Btu/h · DuctedTop 10%2.57
- 8BOVA-60MTB-M19Ewith ducted air handler AE*L+DM60B4Z+TXV+TDRBosch4 tons · 49,000 Btu/h · DuctedTop 10%2.47
- 9CHV6-RS48URBMHHCooper&Hunter (sold as Cooper & Hunter)4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
- 10AVW-48F3DAH2Hisense4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
53 ducted, 3.5–4.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view