DOE CCHP: which heat pumps meet it?
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge. 2.6% of certified models (322, about 1 in 40) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Challenge specification
- Efficiency on a 5°F day (COP at 5°F): 2.1 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 100% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
A model counts when at least one of its certified pairings meets every line on its own. Requirements not published in AHRI ratings (cut-in temperature, GWP, controls) are not checked. Source: U.S. Department of Energy
- Up to 1.5 tons171 of 4,712 models4%
- 2 tons38 of 1,747 models2%
- 2.5–3 tons58 of 2,722 models2%
- 3.5–4.5 tons53 of 2,687 models2%
- 5 tons and up2 of 458 models0%
All sizes: 2.6%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ductless, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
- 1CHV6-RS48URBMHHCooper&Hunter (sold as Cooper & Hunter)4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
- 2CHV6-RS48URBMHHCooper&Hunter (sold as Cooper & Hunter)4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
- 3AVW-48F3DAH2Hisense4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
- 4AVW-48F3DAH2Hisense4 tons · 48,000 Btu/h · DuctlessTop 10%2.40
- 5KUMXA481ALG4 tons · 48,000 Btu/h · DuctlessTop 10%2.34
- 6KUMXA481ALG4 tons · 48,000 Btu/h · DuctlessTop 10%2.34
- 7KUMXA421ALG3.5 tons · 42,000 Btu/h · DuctlessTop 10%2.29
- 8KUMXA421ALG3.5 tons · 42,000 Btu/h · DuctlessTop 10%2.29
- 9FPHFR48A3Dwith ducted air handler FPHFA48A3DFriedrich4 tons · 48,000 Btu/h · DuctedGood2.10
- 10ZRUM048GSS0LG4 tons · 48,000 Btu/h · DuctlessGreat2.10
12 ductless, 3.5–4.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.