Both views use the same certified data. This device remembers your choice.
AireForce heat pumps: how do their ratings compare?
A typical AireForce heat pump beats 40% of similar heat pumps (same size and type), which is well below average. AireForce has 70 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
40%
of similar heat pumps beaten by its typical model
Well below averageAireForce has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 75 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 32%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 41%
- Winter-long heating efficiencyHSPF2Beats 39%
- Summer-long cooling efficiencySEER2Beats 42%
- Hot-day cooling efficiencyEER2Beats 42%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
50%
meet CEE 2025 Tier 1, the level many utility rebates use.
35 models. All brands: 57%.
49%
meet Xcel Energy Colorado’s cold-climate rebate levels.
34 models. All brands: 53%.
3%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
2 models. All brands: 3%.
AireForce all-around best, by size
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
13 of AireForce’s 13 models of this size and type have all five ratings.
- 1UXH24-36MSK3IHwith ducted air handler UMD36MSK3IHAireForce3 tons · 34,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 18.2 (SEER2)
- Good
- Hot-day cooling
- 11.2 (EER2)
- Below the middle
- 2DXH30FMK3IHAireForce2.5 tons · 28,400 Btu/h · DuctedCold-climate pick, score 47.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.88 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3DXH36FMK3IHAireForce2.5 tons · 32,000 Btu/h · DuctedCold-climate pick, score 52.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 4DXH42FMK3IHAireForce3 tons · 38,000 Btu/h · DuctedCold-climate pick, score 49.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 5AC-36-HP-E-32with ducted air handler AC-36-AH-E-32AireForce3 tons · 35,000 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 66% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 8.6 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
Advanced view: AireForce’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.
Open the advanced view