Skip to content

Proair heat pumps: how do their ratings compare?

A typical Proair heat pump beats 53% of similar heat pumps (same size and type), which is about average. Proair has 30 heat pump models in this list.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Overall score

53%

of similar heat pumps beaten by its typical model

About average

Proair has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 40 models with every rating.

Proair, rating by ratingStrongest on winter-long heating efficiency (beats 60%), weakest on hot-day cooling efficiency (beats 46%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 56%
  • Winter-long heating efficiencyHSPF2Beats 60%
  • Summer-long cooling efficiencySEER2Beats 56%
  • Hot-day cooling efficiencyEER2Beats 46%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 70%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    21 models. All brands: 57%.

    See them

  • 67%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    20 models. All brands: 53%.

    See them

  • 0%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    None of its models. All brands: 3%.

Proair all-around best, by size

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

7 of Proair’s 7 models of this size and type have all five ratings.

  1. 1PMUL-H5P-36HP-MProair3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    106% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.4 (HSPF2)
    Top 10%
    Cooling efficiency
    19.4 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    83.9score / 100Heating 83 · Cooling 85
  2. 2PMUL-H4P-27HP-MProair2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 73.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    77.8score / 100Heating 73 · Cooling 83
  3. 3PMUL-A5P-36HP-MProair3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 60.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    70.0score / 100Heating 60 · Cooling 80
  4. 4P30-30CENHP-R454with ducted air handler PAC-36B24T-INTProair2.5 tons · 29,000 Btu/h · DuctedCold-climate pick, score 68.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    107% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.6 (HSPF2)
    Great
    Cooling efficiency
    16.0 (SEER2)
    Below the middle
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    53.2score / 100Heating 68 · Cooling 38
  5. 5P30-36CENHP-R454with ducted air handler PAC-36B24T-INTProair3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 63.0Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.4 (HSPF2)
    Great
    Cooling efficiency
    15.8 (SEER2)
    Below the middle
    Hot-day cooling
    10.7 (EER2)
    Below the middle
    47.8score / 100Heating 63 · Cooling 33

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

Advanced view: Proair’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter