Skip to content

Bosch vs iCongo heat pumps

Measured against models of the same size and duct type, Bosch scores higher on 6 of the 6 ratings. Bosch has 47 outdoor models, iCongo has 47 outdoor models. iCongo has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Bosch and iCongo on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Bosch scores higher on 6 of the 6 ratings.
  • Bosch
  • iCongo
  • Other ranked manufacturers
BoschiCongo

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBoschiCongo
Efficiency index62% (higher)median — · 3rd ranked42% (higher)median —
COP at 5°F63% (higher)median 2.10 · 5th ranked37% (higher)median 1.82
Capacity retention at 5°F62% (higher)median 75% · 4th ranked52% (higher)median 68%
HSPF268% (higher)median 9.5 · 4th ranked49% (higher)median 8.4
SEER265% (higher)median 19.0 · 3rd ranked48% (higher)median 15.8
EER255% (higher)median 11.7 · 12th ranked28% (higher)median 10.0
Heating capacity at 5°F65% (higher)median 23,000 Btu/h · 4th ranked55% (higher)median 25,200 Btu/h
Outdoor models4747
AHRI certifications1,78997

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBoschiCongo
CEE 2025 Tier 1 (Split ASHP)93.6%44 models31.9%15 models
CEE 2026 Tier 1 (Split ASHP)91.5%43 models31.9%15 models
CEE Advanced Tier (Split ASHP)14.9%7 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)83%39 models31.9%15 models
DOE Cold Climate Heat Pump Challenge14.9%7 models0%0 models
ENERGY STAR Cold Climate85.1%40 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • Bosch
  • iCongo
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBoschiCongo
Ducted, up to 1.5 tons10 · index 70%3 · index 35%
Ducted, 2 tons7 · index 65%10 · index 43%
Ducted, 2.5–3 tons12 · index 55%12 · index 37%
Ducted, 3.5–4.5 tons11 · index 68%22 · index 46%
Ducted, 5 tons and up4 · index 63%None
Non-ducted, up to 1.5 tons9 · index 71%None
Non-ducted, 2 tons3 · index 64%None
Non-ducted, 2.5–3 tons10 · index 51%None
Non-ducted, 3.5–4.5 tons3 · index 60%None
Non-ducted, 5 tons and up2 · index 35%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBoschCold-climate score, best modeliCongoCold-climate score, best model
Ducted, up to 1.5 tons80.1(50 is the typical model of its size class) (higher)BMS500-AAS009-1CSXRDwith ducted air handler BMS500-AAU009-1AHDXD10 of 10 models qualify · AHRI 21522329745.5(50 is the typical model of its size class)ZOC-18HIN4-M-SE18with ducted air handler ZVMQFA-18HIN4L-M-SE152 of 3 models qualify · AHRI 217902692
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)BMS500-AAS024-1CSXHDwith ducted air handler BMS500-AAU024-1AHDXD8 of 8 models qualify · AHRI 21522329170.4(50 is the typical model of its size class)ZWDA-24HI1N4-M-SE18Also listed as ZWDA-24HI1N4-M-SE189 of 10 models qualify · AHRI 217022533
Ducted, 2.5–3 tons83.7(50 is the typical model of its size class) (higher)BOVB-36MTB-M19Ewith ducted air handler BIVB-36MCB-M19X8 of 12 models qualify · AHRI 21790312169.2(50 is the typical model of its size class)ZOD-36HIN4-M-SE18Hwith ducted air handler ZVMXFB-36HI1N4-C-M-SE183 of 12 models qualify · AHRI 218647967
Ducted, 3.5–4.5 tons90.9(50 is the typical model of its size class) (higher)BOVA-60MTB-M19Ewith ducted air handler AE*L+DM60B4Z+TXV+TDR10 of 10 models qualify · AHRI 21869351866.2(50 is the typical model of its size class)ZODA-48HIN4-M-SE18H*with ducted air handler ZVMXFC-48HI1N4-C-M-SE1811 of 22 models qualify · AHRI 218673039
Ducted, 5 tons and up63.4(50 is the typical model of its size class)BPBA-60RCB-M18SAlso listed as BPBB-60RTB-M18S3 of 4 models qualify · AHRI 216011943No models in this size class
Non-ducted, up to 1.5 tons97.5(50 is the typical model of its size class)BMS500-AAS009-1CSXRDwith ductless indoor unit BMS500-AAU006-1AHWXD8 of 9 models qualify · AHRI 217656832No models in this size class
Non-ducted, 2 tons89.4(50 is the typical model of its size class)BMS500-AAS024-1CSXHDwith ductless indoor unit BMS500-AAU024-1AHCXD3 of 3 models qualify · AHRI 215223292No models in this size class
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class)BMS500-AAM036-1CSXHD8 of 10 models qualify · AHRI 215223324No models in this size class
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)BMS500-AAM048-1CSXHD3 of 3 models qualify · AHRI 215223327No models in this size class
Non-ducted, 5 tons and up50.6(50 is the typical model of its size class)BOHA-60MTB-M18S2 of 2 models qualify · AHRI 218059677No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBoschAll-around score, best modeliCongoAll-around score, best model
Ducted, up to 1.5 tons86.7(50 is the typical model of its size class) (higher)BMS500-AAS009-1CSXHDwith ducted air handler BMS500-AAU009-1AHDXD10 of 10 models have all five ratings · AHRI 21522328138.9(50 is the typical model of its size class)ZOC-18HIN4-M-SE18with ducted air handler ZVMXFA-18HI1N4-C-M-SE183 of 3 models have all five ratings · AHRI 217022537
Ducted, 2 tons85.6(50 is the typical model of its size class) (higher)BOVA-36RTB-M20Swith ducted air handler L(E,G)M36FJ9 of 9 models have all five ratings · AHRI 21788795176.9(50 is the typical model of its size class)ZOT6P-24HIN4-M-SE20with ducted air handler ZVMXFB-24HI1N4-M-SE2010 of 10 models have all five ratings · AHRI 217902688
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class) (higher)BMS500-AAM036-1CSXHD10 of 10 models have all five ratings · AHRI 21522332354.1(50 is the typical model of its size class)ZOT6P-36HIN4-M-SE20with ducted air handler ZVMXFB-36HI1N4-M-SE2012 of 12 models have all five ratings · AHRI 217902689
Ducted, 3.5–4.5 tons86.3(50 is the typical model of its size class) (higher)BOVA-60MTB-M19Ewith ducted air handler (V,R)60H210P19*+TXV+AEFE511 of 11 models have all five ratings · AHRI 21879693865.5(50 is the typical model of its size class)ZWDA-48HI1N4-M-SE18Also listed as ZWDB-48HI1N4S4-M-SE1822 of 22 models have all five ratings · AHRI 217022535
Ducted, 5 tons and up70.1(50 is the typical model of its size class)BPBA-60RCB-M18SAlso listed as BPBB-60RTB-M18S4 of 4 models have all five ratings · AHRI 216011943No models in this size class
Non-ducted, up to 1.5 tons95.8(50 is the typical model of its size class)BMS500-AAS009-1CSXRDwith ductless indoor unit BMS500-AAU006-1AHWXD9 of 9 models have all five ratings · AHRI 217656832No models in this size class
Non-ducted, 2 tons86.8(50 is the typical model of its size class)BMS500-AAS024-1CSXRDwith ductless indoor unit BMS500-AAU024-1AHWXD3 of 3 models have all five ratings · AHRI 215223306No models in this size class
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class)BMS500-AAM036-1CSXHD10 of 10 models have all five ratings · AHRI 215223322No models in this size class
Non-ducted, 3.5–4.5 tons75.6(50 is the typical model of its size class)BMS500-AAM048-1CSXHD3 of 3 models have all five ratings · AHRI 215223325No models in this size class
Non-ducted, 5 tons and up36.0(50 is the typical model of its size class)BOHA-60MTB-M18S2 of 2 models have all five ratings · AHRI 218059677No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBoschiCongo
COP at 5°Fbeats 99% · 2.73BOHA-24MTB-M18SDucted, up to 1.5 tonsbeats 99% · 2.80ZOT6PA-42HN4-M-SE14.3Ducted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 100% · 127%BOVA-60MTB-M19EDucted, 3.5–4.5 tonsbeats 99% · 115%ZOD-36HIN4-M-SE18HDucted, 2.5–3 tons
HSPF2beats 99% · 11.0BMS500-AAM048-1CSXHDDucted, 3.5–4.5 tonsbeats 87% · 10.1ZOD-36HIN4-M-SE18HDucted, 2.5–3 tons
SEER2beats 97% · 25.0BMS500-AAM027-1CSXRDNon-ducted, 2.5–3 tonsbeats 86% · 19.3ZOT6P-36HIN4-M-SE20Ducted, 2.5–3 tons
EER2beats 100% · 18.1BMS500-AAS009-1CSXRDNon-ducted, up to 1.5 tonsbeats 81% · 12.5ZOT6P-24HIN4-M-SE20Ducted, 2 tons
Heating capacity at 5°Fbeats 100% · 64,000 Btu/hBOVA-60MTB-M19EDucted, 3.5–4.5 tonsbeats 100% · 42,500 Btu/hZOD-36HIN4-M-SE18HDucted, 2.5–3 tons

More comparisons