Skip to content

InfinityLiving vs PolarWave heat pumps

Measured against models of the same size and duct type, InfinityLiving and PolarWave split the 6 ratings 0–0. InfinityLiving has 20 outdoor models, PolarWave has 20 outdoor models. InfinityLiving and PolarWave have no QMID on file and are not ranked. They share hardware: 26 equipment families appear under both names.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
InfinityLiving and PolarWave on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, InfinityLiving and PolarWave split the 6 ratings 0–0.
  • InfinityLiving
  • PolarWave
  • Other ranked manufacturers
Infinity…PolarWave

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingInfinityLivingPolarWave
Efficiency index51%median —51%median —
COP at 5°F52%median 2.0052%median 2.00
Capacity retention at 5°F44%median 71%44%median 71%
HSPF258%median 9.558%median 9.5
SEER257%median 19.257%median 19.2
EER242%median 11.242%median 11.2
Heating capacity at 5°F55%median 21,600 Btu/h55%median 21,600 Btu/h
Outdoor models2020
AHRI certifications2626

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardInfinityLivingPolarWave
CEE 2025 Tier 1 (Split ASHP)75%15 models75%15 models
CEE 2026 Tier 1 (Split ASHP)75%15 models75%15 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)65%13 models65%13 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate70%14 models70%14 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • InfinityLiving
  • PolarWave
  • All models of the group
Ducted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeInfinityLivingPolarWave
Ducted, 2 tons3 · index 60%3 · index 60%
Ducted, 2.5–3 tons3 · index 60%3 · index 60%
Ducted, 3.5–4.5 tons5 · index 53%5 · index 53%
Non-ducted, up to 1.5 tons6 · index 48%6 · index 48%
Non-ducted, 2 tons3 · index 44%3 · index 44%
Non-ducted, 2.5–3 tons2 · index 32%2 · index 32%
Non-ducted, 3.5–4.5 tons1 · index 53%1 · index 53%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeInfinityLivingCold-climate score, best modelPolarWaveCold-climate score, best model
Ducted, 2 tons66.3(50 is the typical model of its size class)EZ-24-HPBwith ducted air handler EZ-24-AHB3 of 3 models qualify · AHRI 21698083766.3(50 is the typical model of its size class)EZ-24-HPBwith ducted air handler EZ-24-AHB3 of 3 models qualify · AHRI 216980861
Ducted, 2.5–3 tons73.1(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models qualify · AHRI 21698083873.1(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models qualify · AHRI 216980862
Ducted, 3.5–4.5 tons70.5(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models qualify · AHRI 21698091770.5(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models qualify · AHRI 216980937
Non-ducted, up to 1.5 tons73.1(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB3 of 6 models qualify · AHRI 21698087673.1(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB3 of 6 models qualify · AHRI 216980906
Non-ducted, 2 tons42.8(50 is the typical model of its size class)EZ-27Z-M3B1 of 3 models qualify · AHRI 21698091242.8(50 is the typical model of its size class)EZ-27Z-M3B1 of 3 models qualify · AHRI 216980932
Non-ducted, 2.5–3 tons41.3(50 is the typical model of its size class)EZ-36Z-M4B1 of 2 models qualify · AHRI 21698091341.3(50 is the typical model of its size class)EZ-36Z-M4B1 of 2 models qualify · AHRI 216980933
Non-ducted, 3.5–4.5 tons45.0(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models qualify · AHRI 21698091845.0(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models qualify · AHRI 216980938

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeInfinityLivingAll-around score, best modelPolarWaveAll-around score, best model
Ducted, 2 tons68.3(50 is the typical model of its size class)EZ-27Z-M3B3 of 3 models have all five ratings · AHRI 21698091168.3(50 is the typical model of its size class)EZ-27Z-M3B3 of 3 models have all five ratings · AHRI 216980931
Ducted, 2.5–3 tons67.3(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models have all five ratings · AHRI 21698083867.3(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models have all five ratings · AHRI 216980862
Ducted, 3.5–4.5 tons80.2(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models have all five ratings · AHRI 21698091780.2(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models have all five ratings · AHRI 216980937
Non-ducted, up to 1.5 tons73.3(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB6 of 6 models have all five ratings · AHRI 21698087673.3(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB6 of 6 models have all five ratings · AHRI 216980906
Non-ducted, 2 tons56.2(50 is the typical model of its size class)EZ-24ZPL-HP230Bwith ductless indoor unit EZ-24W-MB3 of 3 models have all five ratings · AHRI 21698087756.2(50 is the typical model of its size class)EZ-24ZPL-HP230Bwith ductless indoor unit EZ-24W-MB3 of 3 models have all five ratings · AHRI 216980907
Non-ducted, 2.5–3 tons53.2(50 is the typical model of its size class)EZ-36Z-M4B2 of 2 models have all five ratings · AHRI 21698091353.2(50 is the typical model of its size class)EZ-36Z-M4B2 of 2 models have all five ratings · AHRI 216980933
Non-ducted, 3.5–4.5 tons52.8(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models have all five ratings · AHRI 21698091652.8(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models have all five ratings · AHRI 216980936

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingInfinityLivingPolarWave
COP at 5°Fbeats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tonsbeats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 91% · 105%EZ-36-HPBDucted, 2.5–3 tonsbeats 91% · 105%EZ-36-HPBDucted, 2.5–3 tons
HSPF2beats 91% · 10.3EZ-36-HPBDucted, 2.5–3 tonsbeats 91% · 10.3EZ-36-HPBDucted, 2.5–3 tons
SEER2beats 91% · 20.0EZ-48Z-M5BDucted, 3.5–4.5 tonsbeats 91% · 20.0EZ-48Z-M5BDucted, 3.5–4.5 tons
EER2beats 83% · 12.0EZ-48Z-M5BDucted, 3.5–4.5 tonsbeats 83% · 12.0EZ-48Z-M5BDucted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 97% · 39,000 Btu/hEZ-36-HPBDucted, 2.5–3 tonsbeats 97% · 39,000 Btu/hEZ-36-HPBDucted, 2.5–3 tons

More comparisons