Skip to content

Liberty Heating & Air Conditioning vs Pioneer: heat pump ratings compared

Against heat pumps of the same size and type, a typical Liberty Heating & Air Conditioning model beats 58% and a typical Pioneer model 48%. Liberty Heating & Air Conditioning rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Liberty Heating & Air Conditioning

58%

of similar heat pumps beaten by its typical model

Above average

6 models listed

Pioneer

48%

of similar heat pumps beaten by its typical model

About average

46 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLiberty Heating & Air Conditioning: Beats 52%Pioneer: Beats 42%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLiberty Heating & Air Conditioning: Beats 29%Pioneer: Beats 44%
  • Winter-long heating efficiencyHSPF2Liberty Heating & Air Conditioning: Beats 55%Pioneer: Beats 58%
  • Summer-long cooling efficiencySEER2Liberty Heating & Air Conditioning: Beats 51%Pioneer: Beats 57%
  • Hot-day cooling efficiencyEER2Liberty Heating & Air Conditioning: Beats 91%Pioneer: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Liberty Heating & Air Conditioning
    50%
    Pioneer
    74%
  • Xcel CC

    Liberty Heating & Air Conditioning
    0%
    Pioneer
    70%
  • CEE Advanced

    Liberty Heating & Air Conditioning
    0%
    Pioneer
    0%
  • ENERGY STAR CC

    Liberty Heating & Air Conditioning
    0%
    Pioneer
    54%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Liberty Heating & Air Conditioning

No ducted, 2.5 to 3 tons model from Liberty Heating & Air Conditioning.

Pioneer

  1. 1YN040GLSI24M4GPioneer3 tons · 34,000 Btu/h · DuctedCold-climate pick, score 62.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    64.1score / 100Heating 62 · Cooling 66
  2. 2YN030GLSI24M3GPioneer2.5 tons · 27,000 Btu/h · DuctedCold-climate pick, score 49.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.88 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.1 (EER2)
    Below the middle
    60.0score / 100Heating 49 · Cooling 71
  3. 3YN036GMSI20RUGwith ducted air handler RB036GMSILDFHGPioneer3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets CEE 2025
    Heat kept at 5°F
    64% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.2 (HSPF2)
    Great
    Cooling efficiency
    18.7 (SEER2)
    Great
    Hot-day cooling
    10.1 (EER2)
    Below the middle
    58.0score / 100Heating 69 · Cooling 47

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter