Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

63 models

Sorted by manufacturer and model.
Page 1 of 3
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1CH-ALT18HP24V-230VOCooper&Hunterwith ducted air handler CH-MP18AHU24V1.5 tons18,000 Btu/h · Ducted2.1766%8.317.09.511,900None3218470839
2CH-ALT24HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP24AHU24V2 tons23,000 Btu/h · Ducted1.7871%8.716.48.016,300ES CC4218470841
3CH-ALT30HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP30AHU24V2.5 tons30,000 Btu/h · Ducted1.9871%9.217.69.121,200ES CC7218470842
4CH-ALT36HP24V-230VOCooper&Hunterwith ducted air handler CH-MP36AHU24V3 tons34,000 Btu/h · Ducted2.2665%8.615.28.122,200None2218470840
5CH-ALT48HP24V-230VOCooper&Hunterwith ducted air handler CH-ACL30-36B3.5 tons40,000 Btu/h · Ducted1.9384%8.014.39.033,600ES CC3218817467
6CH-ALT60HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP60AHU24V4.5 tons54,000 Btu/h · Ducted1.8270%8.116.08.337,800ES CC3218470844
7CH-PQ18-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ18AHU1.5 tons18,000 Btu/h · Ducted2.12103%10.119.012.518,600CEE 25CEE 26CEE AdvXcelDOEES CC8215864120
8CH-PQ24-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ24AHU2 tons24,000 Btu/h · Ducted2.1486%10.018.612.020,600CEE 25CEE 26XcelES CC11215864121
9CH-PQ33-230VOCooper&Hunter · CH Serieswith ducted air handler CH-STM30AHU24V2.5 tons30,000 Btu/h · Ducted2.00100%10.217.511.732,000CEE 25CEE 26XcelES CC12218470847
10CH-PQ36-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ36AHU3 tons36,000 Btu/h · Ducted2.0691%10.017.712.032,600CEE 25CEE 26XcelES CC3215864123
11CH-PQ36X-230VOCooper&Hunter · CH Serieswith ducted air handler CH-ACL30-36B3 tons36,000 Btu/h · Ducted1.9095%9.415.810.736,000CEE 25CEE 26XcelES CC8217732885
12CH-PQ48-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ48AHU4 tons48,000 Btu/h · Ducted2.00100%9.517.512.048,000CEE 25CEE 26XcelES CC9215864124
13CH-PQ55-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ55AHU4.5 tons54,000 Btu/h · Ducted1.9098%9.517.512.054,000CEE 25CEE 26XcelES CC6215864125
14CH-R18MES-230VOCooper&Hunter · CH Series1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3215864256
15CH-R28MES-230VOCooper&Hunter · CH Series2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3215864257
16CH-R36LCU-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH36LCCT3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.09.626,600CEE 25CEE 26XcelES CC5215864198
17CH-R36MES-230VOCooper&Hunter · CH Series3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3215864260
18CH-R48LCU-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RSH48LCCT4 tons48,000 Btu/h · Ducted and non-ducted2.0076%9.817.110.038,000CEE 25CEE 26XcelES CC5215864199
19CH-R48MES-230VOCooper&Hunter · CH Series4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.412.038,000CEE 25CEE 26XcelES CC3215864264
20CH-R60LCU-230VOCooper&Hunterwith ducted air handler CH-RS60LCDT-HS5 tons58,000 Btu/h · Ducted and non-ducted2.2067%9.717.010.040,000CEE 25CEE 263215864231
21CH-R60MES-230VOCooper&Hunter5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2065%9.522.010.039,000CEE 25CEE 263215864266
22CH-REL30-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS30MAHU2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.717.011.020,400CEE 25CEE 264215864133
23CH-REL36-230VOCooper&Hunterwith ductless indoor unit CH-R36MELVWM-230VI3 tons36,000 Btu/h · Non-ducted2.0267%9.119.59.324,000None3215864143
24CH-RES06-115VOCooper&Hunter · CH Serieswith ductless indoor unit CH-R06OLVWM-115VI1 ton9,000 Btu/h · Non-ducted2.2173%10.724.515.07,300CEE 25CEE 26XcelES CC1215864144
25CH-RES09-115VOCooper&Hunter · CH Serieswith ductless indoor unit CH-R09OLVWM-115VI1 ton9,000 Btu/h · Non-ducted2.2173%10.724.515.07,300CEE 25CEE 26XcelES CC2215864145

Download CSV of the matching modelsAll 63 matching models, every page, in this order.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter