25 models
Sorted by manufacturer and model.
| # · Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|
| 118WHHPBAFirst Co.with ducted air handler 26UCX(*,E,Q,R,W)*X | 1.5 tons15,400 Btu/h · Ducted | 1.74 | 45% | 6.5 | 12.0 | 10.4 | 6,600 | None | 17 | 217036567 |
| 224WHHPBAFirst Co.with ducted air handler 32UCX(*,E,Q,R,W)*X | 2 tons21,600 Btu/h · Ducted | 2.02 | 57% | 6.5 | 12.5 | 11.4 | 9,400 | None | 18 | 217036571 |
| 330WHHPBAFirst Co.with ducted air handler 37CLX(*,Q,W) | 2.5 tons27,200 Btu/h · Ducted | 1.80 | 48% | 6.8 | 13.2 | 11.3 | 11,500 | None | 8 | 216831933 |
| 4EHE09***D***AFirst Co. | 1 ton9,000 Btu/h · Ducted | 1.80 | 45% | 6.3 | 11.9 | 10.0 | 4,000 | None | 1 | 216831957 |
| 5EHE09***E***AFirst Co. | 1 ton9,000 Btu/h · Ducted | 1.80 | 45% | 6.3 | 11.9 | 10.0 | 4,000 | None | 1 | 218364946 |
| 6EHE12***D***AFirst Co. | 1 ton11,500 Btu/h · Ducted | 2.00 | 45% | 6.3 | 11.9 | 10.0 | 5,000 | None | 1 | 216831958 |
| 7EHE12***E***AFirst Co. | 1 ton11,500 Btu/h · Ducted | 2.00 | 45% | 6.3 | 11.9 | 10.0 | 5,000 | None | 1 | 218364947 |
| 8EHE18***D***AFirst Co. | 1.5 tons17,500 Btu/h · Ducted | 2.00 | 49% | 6.3 | 11.9 | 10.0 | 8,000 | None | 1 | 216831959 |
| 9EHE18***E***AFirst Co. | 1.5 tons17,500 Btu/h · Ducted | 2.00 | 49% | 6.3 | 11.9 | 10.0 | 8,000 | None | 1 | 218364948 |
| 10EHE24***D***BFirst Co. | 2 tons24,400 Btu/h · Ducted | 2.00 | 51% | 6.3 | 11.9 | 10.0 | 12,000 | None | 1 | 216831960 |
| 11EHE24***E***BFirst Co. | 2 tons24,400 Btu/h · Ducted | 2.00 | 51% | 6.3 | 11.9 | 10.0 | 12,000 | None | 1 | 218368488 |
| 12EHE30***D***BFirst Co. | 2 tons26,400 Btu/h · Ducted | 1.90 | 51% | 6.3 | 11.9 | 10.0 | 13,000 | None | 1 | 216831961 |
| 13EHE30***E***BFirst Co. | 2 tons26,400 Btu/h · Ducted | 1.90 | 51% | 6.3 | 11.9 | 10.0 | 13,000 | None | 1 | 218364949 |
| 14EPE12***DFirst Co. | 1 ton11,200 Btu/h · Ducted | 1.60 | 40% | 6.3 | 11.9 | 10.0 | 4,000 | None | 1 | 218036115 |
| 15EPE12***EFirst Co. | 1 ton11,200 Btu/h · Ducted | 1.60 | 40% | 6.3 | 11.9 | 10.0 | 4,000 | None | 1 | 218364950 |
| 16EPE18***DFirst Co. | 1.5 tons18,000 Btu/h · Ducted | 1.60 | 41% | 6.3 | 11.9 | 10.0 | 6,500 | None | 1 | 218036116 |
| 17EPE18***EFirst Co. | 1.5 tons18,000 Btu/h · Ducted | 1.60 | 41% | 6.3 | 11.9 | 10.0 | 6,500 | None | 1 | 218364951 |
| 18EPE24***DFirst Co. | 2 tons23,000 Btu/h · Ducted | 1.80 | 54% | 6.3 | 11.9 | 9.5 | 11,500 | None | 1 | 218036117 |
| 19EPE24***EFirst Co. | 2 tons23,000 Btu/h · Ducted | 1.80 | 54% | 6.3 | 11.9 | 9.5 | 11,500 | None | 1 | 218364952 |
| 20EPE30***DFirst Co. | 2.5 tons28,000 Btu/h · Ducted | 1.90 | 54% | 6.3 | 11.9 | 9.5 | 14,500 | None | 1 | 218036118 |
| 21EPE30***EFirst Co. | 2.5 tons28,000 Btu/h · Ducted | 1.90 | 54% | 6.3 | 11.9 | 9.5 | 14,500 | None | 1 | 218364953 |
| 22EVE12***DFirst Co. | 1 ton11,800 Btu/h · Ducted | 2.20 | 85% | 9.0 | 17.0 | 13.0 | 10,100 | CEE 25CEE 26Xcel | 1 | 218082618 |
| 23EVE18***DFirst Co. | 1.5 tons17,300 Btu/h · Ducted | 2.10 | 80% | 9.0 | 16.0 | 11.0 | 14,000 | CEE 25CEE 26Xcel | 1 | 218082619 |
| 24EVE24***DFirst Co. | 2 tons23,400 Btu/h · Ducted | 2.00 | 83% | 9.0 | 16.0 | 10.8 | 19,500 | CEE 25CEE 26Xcel | 1 | 218082620 |
| 25EVE30***DFirst Co. | 2.5 tons27,600 Btu/h · Ducted | 2.00 | 80% | 8.5 | 15.5 | 10.0 | 22,400 | Xcel | 1 | 218082621 |