Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

45 models

Sorted by manufacturer and model.
Page 1 of 2
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1ODUM3OD31-18HFN10-M1XD-DKepler · ODU Series1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3218853758
2ODUM3OX430-18HFN10-M1-DKepler · ODU Series1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3218853745
3ODUM4OD30-27HFN10-M1D-DKepler · ODU Series2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3218853746
4ODUM4OD31-27HFN10-M1XD-DKepler · ODU Series2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3218853761
5ODUM5OD30-36HFN10-M1D-DKepler · ODU Series3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3218853749
6ODUM5OX631-36HFN10-M1XD-DKepler · ODU Series3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3218853764
7ODUM6OE30-48HFN10-M1D-DKepler · ODU Series4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.412.038,000CEE 25CEE 26XcelES CC3218853753
8ODUM6OE30-60HFN10-M1D-DKepler · ODU Series5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2065%9.522.010.039,000CEE 25CEE 263218853755
9ODUM6OE31-48HFN10-M1XD-DKepler · ODU Series4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.012.047,000CEE 25CEE 26XcelES CC3218853767
10ODUM6OE31-53HFN10-M1XD-DKepler · ODU Series4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.011.748,000CEE 25CEE 26XcelES CC3218853771
11ODUMOD30-24HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMSEPD-24HRFN10-M1-D2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.014.019,600CEE 25CEE 26XcelES CC3218851003
12ODUMOD30-24HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPD-24HRFN10-M1-D2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.013.024,200CEE 25CEE 26XcelES CC3218851008
13ODUMOD30-30HFN10-M1EKepler · ODU Serieswith ductless indoor unit IDUMSABF-30HRFN10-M1E2.5 tons30,000 Btu/h · Non-ducted1.8866%9.220.011.019,700CEE 25CEE 261218850992
14ODUMOD30-30HFN10-M3Keplerwith ducted air handler IDUMVBC-30HWFN10-MC3E-D2.5 tons30,000 Btu/h · Ducted2.0062%8.517.010.719,100CEE 257218853735
15ODUMOD30-30HFN10-M3XKepler · ODU Serieswith ducted air handler IDUMVBC-30HWFN10-MC3E-D2.5 tons30,000 Btu/h · Ducted1.9696%10.016.811.732,600CEE 25CEE 26XcelES CC8218853729
16ODUMOD30-33HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPD-33HRFN10-M1-D3 tons33,000 Btu/h · Non-ducted1.9897%10.519.512.035,000CEE 25CEE 26XcelES CC1218851009
17ODUMOD30-36HFN10-M1EKeplerwith ductless indoor unit IDUMSABFM-36HRFN10-M1E3 tons36,000 Btu/h · Non-ducted1.8059%8.518.09.021,400None1218850993
18ODUMOD30-36HFN10-M3Kepler · ODU Serieswith ducted air handler IDUMVBM-36B24T4N103 tons36,000 Btu/h · Ducted2.0076%8.514.79.627,200CEE 25CEE 26XcelES CC7218853721
19ODUMOD30-36HFN10-M3XKepler · ODU Serieswith ducted air handler IDUMVBC-36HWFN10-MC3E-D3 tons36,000 Btu/h · Ducted1.8586%8.216.510.032,000XcelES CC1218853730
20ODUMOE30-45HFN10-M3XKepler · ODU Serieswith ducted air handler IDUMVBM-60D28T6N104 tons47,000 Btu/h · Ducted1.8374%8.115.210.043,000XcelES CC2218853710
21ODUMOE30-48HFN10-M2XKepler · ODU Serieswith ducted air handler IDUMTJ-48HWFN10-M2-D4 tons48,000 Btu/h · Ducted and non-ducted2.0091%10.816.710.447,500CEE 25CEE 26Xcel2218856690
22ODUMOE30-60HFN10-M2XKepler · ODU Serieswith ducted air handler IDUMHJ-60HWFN10-M2-D4.5 tons55,000 Btu/h · Ducted2.1089%10.415.810.253,500Xcel1218856691
23ODUMOE30-60HFN10-M3XKepler · ODU Serieswith ducted air handler IDUMVBM-60D28T6N104 tons47,000 Btu/h · Ducted1.8374%8.115.210.043,000CEE 25CEE 26XcelES CC5218853712
24ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.414.47,800CEE 25CEE 26CEE AdvXcelDOEES CC3218857674
25ODUMOX230-09HFN10-B1EKepler · ODU Serieswith ductless indoor unit IDUMSABA-09HRFN10-B1E1 ton9,000 Btu/h · Non-ducted1.9665%9.021.512.56,500CEE 25CEE 26XcelES CC2218850986

Download CSV of the matching modelsAll 45 matching models, every page, in this order.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter