Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

10 models

Sorted by manufacturer and model.
Page 1 of 1
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1OS-RMS18-230VOOLMO · SIERRA1.5 tons18,000 Btu/h · Non-ducted1.99100%10.022.013.318,000CEE 25CEE 26XcelES CC1217739001
2OS-RMS27-230VOOLMO · SIERRA2.5 tons27,000 Btu/h · Non-ducted1.80100%10.023.012.927,000CEE 25CEE 26XcelES CC1217739002
3OS-RMS36-230VOOLMO · SIERRA3 tons36,000 Btu/h · Non-ducted1.90100%10.022.012.936,000CEE 25CEE 26XcelES CC1217739004
4OS-RMS42-230VOOLMO · SIERRA3.5 tons42,000 Btu/h · Non-ducted1.9075%9.522.012.036,000CEE 25CEE 26XcelES CC1217739003
5OS-SR09-115VOOLMO · SIERRAwith ductless indoor unit OS-09SRW-115VI1 ton9,000 Btu/h · Non-ducted2.0063%9.020.012.56,000CEE 25CEE 262215887333
6OS-SR09-230VOOLMO · SIERRAwith ductless indoor unit OS-A09SRW-230VI1 ton9,000 Btu/h · Non-ducted2.1160%9.022.512.55,400CEE 25CEE 262218752473
7OS-SR12-115VOOLMOwith ductless indoor unit OS-12SRW-115VI1 ton12,000 Btu/h · Non-ducted1.9063%8.518.010.27,500CEE 252215887334
8OS-SR12-230VOOLMOwith ductless indoor unit OS-12SRW-230VI1 ton12,000 Btu/h · Non-ducted2.0063%8.520.011.17,500CEE 25CEE 262215887336
9OS-SR18-230VOOLMO · SIERRAwith ductless indoor unit OS-A18SRW-230VI1.5 tons18,000 Btu/h · Non-ducted2.5374%9.820.012.013,400CEE 25CEE 26Xcel2218752475
10OS-SR24-230VOOLMOwith ductless indoor unit OS-A24SRW-230VI2 tons24,000 Btu/h · Non-ducted1.9876%9.019.510.618,200CEE 25CEE 26Xcel2218752476

Download CSV of the matching modelsAll 10 matching models, every page, in this order.