Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

62 models

Sorted by manufacturer and model.
Page 1 of 3
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
15A5V0X36A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TAMXD05AV412.5 tons29,000 Btu/h · Ducted2.31110%10.320.212.736,000CEE 25CEE 26CEE AdvXcelDOEES CC39218868828
25A5V0X48A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TAMXD05AV413 tons35,800 Btu/h · Ducted2.02104%9.718.412.048,000CEE 25CEE 26XcelES CC43218868908
35A5V0X60A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR4 tons48,500 Btu/h · Ducted2.0587%9.419.211.548,000CEE 25CEE 26XcelES CC30218792280
45A5V0X61A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR4 tons48,000 Btu/h · Ducted2.22100%10.018.011.555,500CEE 25CEE 26CEE AdvXcelDOEES CC22218792282
55A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDR2 tons21,000 Btu/h · Ducted2.87111%8.115.511.724,400CEE 25CEE 26XcelES CC732217155223
65A6H7036A1AMERICAN STANDARDwith ducted air handler D(A,C,E)36B4J+TDR2.5 tons31,200 Btu/h · Ducted2.97134%7.815.511.243,500CEE 25CEE 26XcelES CC1,189217117484
75A6H7048A1AMERICAN STANDARDwith ducted air handler AE*L+CM48B3J+TDR3.5 tons39,500 Btu/h · Ducted2.7464%8.516.011.227,600CEE 25CEE 26XcelES CC669217155229
85A6H7060A1AMERICAN STANDARDwith ducted air handler D(A,C,E)60B4J+TDR4 tons49,500 Btu/h · Ducted2.9262%7.815.210.533,400CEE 25CEE 26XcelES CC422217117491
95A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRP1.5 tons19,500 Btu/h · Ducted2.9398%10.021.011.221,800CEE 25CEE 26XcelES CC167217117128
105A6V0X36A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD06AV41+TDR3 tons36,200 Btu/h · Ducted2.3066%10.521.613.025,400CEE 25CEE 26XcelES CC136217734495
115A6V0X48A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD07BV51+TDR4 tons46,000 Btu/h · Ducted2.2473%10.020.412.034,200CEE 25CEE 26XcelES CC230218788182
125A6V0X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP4 tons50,000 Btu/h · Ducted2.7090%8.519.010.048,000CEE 25CEE 26XcelES CC186217117150
135A6V8X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace S8V2A040M3PCB1.5 tons19,500 Btu/h · Ducted2.9199%8.517.511.022,400CEE 25CEE 26CEE AdvXcelDOEES CC143217117188
145A6V8X36A1AMERICAN STANDARDwith indoor coil D(A,C,E)36B4J+TDR and furnace S9V2C080U5PSC+LRP2.5 tons30,400 Btu/h · Ducted2.8893%7.818.010.031,000CEE 25CEE 26XcelES CC466217117297
155A6V8X48A1AMERICAN STANDARDwith indoor coil D(A,C,E)48B4J+TDR and furnace L8V1C100U5VSB+LRP3.5 tons42,500 Btu/h · Ducted2.8793%8.518.010.542,500CEE 25CEE 26XcelES CC410217117338
165A6V8X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2C080U5VSB+LRP4 tons50,500 Btu/h · Ducted2.7188%8.518.09.849,500CEE 25CEE 26XcelES CC271217117455
175HCL5036B1TRANE · F Serieswith ducted air handler 5TDM5B03AC212 tons24,000 Btu/h · Ducted2.00100%10.018.012.024,000CEE 25CEE 26XcelES CC60217500296
185HCL5060B1TRANE · F Serieswith ducted air handler 5DXCD008AC34 tons47,000 Btu/h · Ducted1.8598%8.816.011.047,000CEE 25CEE 26XcelES CC20217500298
195HPL5024A1AMERICAN STANDARDwith ducted air handler L(E,G)M36GJ2 tons22,000 Btu/h · Ducted2.09110%8.116.011.725,200CEE 25CEE 26XcelES CC248217106836
205HPL5024A1000AATRANE · 5HPL5with ducted air handler 5TEM6B02AV21+TDR2 tons23,000 Btu/h · Ducted1.7578%8.116.011.718,000CEE 25CEE 26XcelES CC15216374485
215HPL5036A1AMERICAN STANDARDwith ducted air handler L(E,G)M36JJ2.5 tons32,000 Btu/h · Ducted2.08105%8.116.011.735,600CEE 25CEE 26XcelES CC223217106837
225HPL5036A1000AATRANE · 5HPL5with ducted air handler 5TEM6D04AV31+TDR3 tons34,000 Btu/h · Ducted1.7579%8.116.011.727,000CEE 25CEE 26XcelES CC14216374486
235HPL5048A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJ3.5 tons42,000 Btu/h · Ducted2.03104%7.815.211.249,500CEE 25CEE 26XcelES CC360217106838
245HPL5048A1000AATRANE · 5HPL5with ducted air handler 5TEM6D06AV41+TDR4 tons46,000 Btu/h · Ducted1.7579%8.116.011.738,000CEE 25CEE 26XcelES CC14216374488
255TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TAMXD05AV412.5 tons29,000 Btu/h · Ducted2.31110%10.320.212.736,000CEE 25CEE 26CEE AdvXcelDOEES CC39218868827

Download CSV of the matching modelsAll 62 matching models, every page, in this order.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter