Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

6 models

Sorted by manufacturer and model.
Page 1 of 1
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
15HCL6024A1000A*Trane/American Standard · M serieswith ducted air handler 5TEM7B02AC21SA2 tons23,800 Btu/h · Ducted1.8082%8.618.614.823,000CEE 25CEE 26XcelES CC1217497619
25HCL9024A1000A*Trane/American Standard · P serieswith ducted air handler 5TEM9C02AC21SA2 tons24,000 Btu/h · Ducted2.1093%8.819.713.626,000CEE 25CEE 26XcelES CC1217497614
35HCL9036A1000A*Trane/American Standard · P serieswith ducted air handler 5TEM9D04AC31SA3 tons36,000 Btu/h · Ducted2.1095%9.221.212.138,000CEE 25CEE 26XcelES CC1217497618
45HCL9048A1000A*Trane/American Standard · P serieswith ducted air handler 5TEM9D06AC31SA4 tons48,000 Btu/h · Ducted1.9087%8.720.210.452,000CEE 25CEE 26XcelES CC1217497615
55HPL6024A1000A*Trane/American Standard · NV serieswith ducted air handler 5TEM7B02AC21SA2 tons22,800 Btu/h · Ducted2.5056%9.419.511.814,000CEE 25CEE 261217456912
65HPL9036A1000A*Trane/American Standard · P serieswith ducted air handler 5TEM9D04AC31SA3 tons36,000 Btu/h · Ducted2.5050%9.219.512.120,000CEE 25CEE 261217497620

Download CSV of the matching modelsAll 6 matching models, every page, in this order.