Skip to content

Check a heat pump’s certified ratings

Type the outdoor unit’s model number from its nameplate, or the AHRI reference number from your quote, to get its certified ratings, how it compares with others of its size, and the rebate standards it meets.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Partial model numbers work. AHRI numbers find the pairing listed for each model.

Ratings

Certified ratings

L03-36K2V-19S-O

LUORISE · AHRI 218079243

Size class: 3 tons · 34,000 Btu/h · Ducted

Numbers are from one AHRI-certified pairing of this outdoor unit with an indoor unit, with ducted air handler L03-36K2V-19S-I.

Efficiency on a 5°F day
1.90
COP at 5°F
Below the middleBeats 33% of its size class
Heating power kept at 5°F
76%
Capacity retention at 5°F
GoodBeats 63% of its size class
Winter-long heating efficiency
9.0
HSPF2
GoodBeats 67% of its size class
Summer-long cooling efficiency
19.0
SEER2
GreatBeats 83% of its size class
Hot-day cooling efficiency
10.0
EER2
Below the middleBeats 12% of its size class
Heat output at 5°F
26,000 Btu/h
Heating capacity at 5°F
GoodBeats 60% of its size class

Cold-climate pick?

Yes. Cold-climate score 55.0 out of 100 in its size class. See the top picks of its size

Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.

All-around score

51.4 out of 100 in its size class (heating 55.0, cooling 47.8). See the all-around best of its size

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Rebate standards

A model meets a standard when at least one of its certified pairings does. Programs can have other rules too.

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Side by side with another model

Only models of the same size class (ducted, 2.5 to 3 tons) can be compared, so their numbers mean the same thing.

What size is my system?

Tons and Btu

A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.

Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Size classes used here

  • Up to 1.5 tonsunder 21,000 Btu/h
  • 2 tons21,000 to 26,999 Btu/h
  • 2.5 to 3 tons27,000 to 38,999 Btu/h
  • 3.5 to 4.5 tons39,000 to 56,999 Btu/h
  • 5 tons and up57,000 Btu/h and up

Advanced view: every model, filtered by brand, standard, size and type, sorted by any rating.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter