Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

6,515 models

Sorted by manufacturer and model.
Page 236 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
58765A5V0X60A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4 tons48,500 Btu/h · Ducted2.0587%9.419.211.548,000CEE 25CEE 26XcelES CC1218792280
58775A5V0X61A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4 tons48,000 Btu/h · Ducted2.22100%10.018.011.555,500CEE 25CEE 26CEE AdvXcelDOEES CC1218792282
58785A6H5036A1AMERICAN STANDARDwith indoor coil DH36T4J and furnace S9V2C100U5PSCTrane3 tons33,600 Btu/h · Ducted3.1970%9.016.312.022,200CEE 25CEE 26Xcel1,625217149038
58795A6H5060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0570%8.115.411.736,600Xcel643217149553
58805A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDRTrane2 tons21,000 Btu/h · Ducted2.87111%8.115.511.724,400CEE 25CEE 26XcelES CC731217155223
58815A6H7036A1AMERICAN STANDARDwith ducted air handler D(A,C,E)36B4J+TDRTrane2.5 tons31,200 Btu/h · Ducted2.97134%7.815.511.243,500CEE 25CEE 26XcelES CC1,188217117484
58825A6H7048A1AMERICAN STANDARDwith ducted air handler AE*L+CM48B3J+TDRTrane3.5 tons39,500 Btu/h · Ducted2.7464%8.516.011.227,600CEE 25CEE 26XcelES CC668217155229
58835A6H7060A1AMERICAN STANDARDwith ducted air handler D(A,C,E)60B4J+TDRTrane4 tons49,500 Btu/h · Ducted2.9262%7.815.210.533,400CEE 25CEE 26XcelES CC422217117491
58845A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRPTrane1.5 tons19,500 Btu/h · Ducted2.9398%10.021.011.221,800CEE 25CEE 26XcelES CC167217117128
58855A6V0X36A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD06AV41+TDRTrane3 tons36,200 Btu/h · Ducted2.3066%10.521.613.025,400CEE 25CEE 26XcelES CC136217734495
58865A6V0X48A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD07BV51+TDRTrane4 tons46,000 Btu/h · Ducted2.2473%10.020.412.034,200CEE 25CEE 26XcelES CC230218788182
58875A6V0X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRPTrane4 tons50,000 Btu/h · Ducted2.7090%8.519.010.048,000CEE 25CEE 26XcelES CC186217117150
58885A6V8X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace S8V2A040M3PCBTrane1.5 tons19,500 Btu/h · Ducted2.9199%8.517.511.022,400CEE 25CEE 26CEE AdvXcelDOEES CC143217117188
58895A6V8X36A1AMERICAN STANDARDwith indoor coil D(A,C,E)36B4J+TDR and furnace S9V2C080U5PSC+LRPTrane2.5 tons30,400 Btu/h · Ducted2.8893%7.818.010.031,000CEE 25CEE 26XcelES CC466217117297
58905A6V8X48A1AMERICAN STANDARDwith indoor coil D(A,C,E)48B4J+TDR and furnace L8V1C100U5VSB+LRPTrane3.5 tons42,500 Btu/h · Ducted2.8793%8.518.010.542,500CEE 25CEE 26XcelES CC410217117338
58915A6V8X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2C080U5VSB+LRPTrane4 tons50,500 Btu/h · Ducted2.7188%8.518.09.849,500CEE 25CEE 26XcelES CC271217117455
58925HCL5024A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5B03AC21Trane2 tons23,000 Btu/h · Ducted1.8884%9.217.011.720,200CEE 25CEE 26XcelES CC2216772255
58935HCL5036A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5B04AC31Trane3 tons34,000 Btu/h · Ducted1.90100%9.417.011.736,000CEE 25CEE 26XcelES CC2216772256
58945HCL5036B1TRANE · F Serieswith ducted air handler 5TDM5B03AC21Trane2 tons24,000 Btu/h · Ducted2.00100%10.018.012.024,000CEE 25CEE 26XcelES CC48217500296
58955HCL5060A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5D06AC41Trane4 tons48,000 Btu/h · Ducted1.8588%9.417.010.842,000CEE 25CEE 26XcelES CC4216772257
58965HCL5060B1TRANE · F Serieswith ducted air handler 5DXCD008AC3Trane4 tons47,000 Btu/h · Ducted1.8598%8.816.011.047,000CEE 25CEE 26XcelES CC20217500298
58975HPL5024A1AMERICAN STANDARDwith ducted air handler L(E,G)M36GJTrane2 tons22,000 Btu/h · Ducted2.09110%8.116.011.725,200CEE 25CEE 26XcelES CC222217106836
58985HPL5024A1000AATRANE · 5HPL5with ducted air handler 5TEM6B02AV21+TDRTrane2 tons23,000 Btu/h · Ducted1.7578%8.116.011.718,000CEE 25CEE 26XcelES CC15216374485
58995HPL5036A1AMERICAN STANDARDwith ducted air handler L(E,G)M36JJTrane2.5 tons32,000 Btu/h · Ducted2.08105%8.116.011.735,600CEE 25CEE 26XcelES CC203217106837
59005HPL5036A1000AATRANE · 5HPL5with ducted air handler 5TEM6D04AV31+TDRTrane3 tons34,000 Btu/h · Ducted1.7579%8.116.011.727,000CEE 25CEE 26XcelES CC14216374486