Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
6,851 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6026MRB536HWDTGM | TGM | 3 tons34,200 Btu/h · Ducted | 1.80 | 64% | 8.1 | 18.0 | 11.0 | 23,000 | CEE 25CEE 26 | 1 | 217194655 |
| 6027MRB560HWDTGM | TGM | 5 tons57,000 Btu/h · Ducted | 1.85 | 70% | 9.0 | 19.0 | 11.2 | 40,000 | CEE 25CEE 26Xcel | 1 | 217194656 |
| 6028MRS5VHT18ASTGM · MRS Serieswith ducted air handler MFC5VHT18S | TGM | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 2.41 | 71% | 11.3 | 20.0 | 13.3 | 14,200 | CEE 25CEE 26XcelES CC | 3 | 217274613 |
| 6029MRS5VHT24ASTGM · MRS Serieswith ductless indoor unit MC45VHT24S | TGM | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.30 | 74% | 10.5 | 22.0 | 12.0 | 18,500 | CEE 25CEE 26XcelES CC | 3 | 217274614 |
| 6030MRS5VHT36ASTGM · MRS Serieswith ductless indoor unit MC45VHT36S | TGM | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | 9.6 | 26,600 | CEE 25CEE 26XcelES CC | 3 | 217274618 |
| 6031MRS5VHT48ASTGM · MRS Serieswith ductless indoor unit MC45VHT48S | TGM | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | 9.5 | 40,500 | CEE 25CEE 26XcelES CC | 3 | 216706042 |
| 6032MTVC2OCN036ATGMwith ducted air handler MTA20C036A | TGM | 3 tons34,200 Btu/h · Ducted | 2.00 | 71% | 9.5 | 19.0 | 12.0 | 24,400 | CEE 25CEE 26Xcel | 1 | 218044247 |
| 6033MTVC2OCN060ATGMwith ducted air handler MTA20C060A | TGM | 4.5 tons52,000 Btu/h · Ducted | 2.00 | 70% | 9.5 | 18.0 | 11.7 | 38,500 | CEE 25CEE 26Xcel | 2 | 218044248 |
| 6034OTV18HN024ATGMwith ducted air handler OTA18C002A | TGM | 2 tons24,000 Btu/h · Ducted | 2.15 | 79% | 8.8 | 18.5 | 12.5 | 19,000 | CEE 25CEE 26Xcel | 1 | 217747066 |
| 6035OTV18HN036ATGMwith ducted air handler OTA18C002A | TGM | 2 tons24,000 Btu/h · Ducted | 2.15 | 79% | 8.8 | 18.5 | 12.5 | 19,000 | CEE 25CEE 26Xcel | 2 | 217747067 |
| 6036OTV18HN048ATGMwith ducted air handler OTA18C006A | TGM | 4 tons47,000 Btu/h · Ducted | 2.30 | 72% | 9.2 | 18.5 | 11.5 | 34,000 | CEE 25CEE 26Xcel | 1 | 217747072 |
| 6037OTV18HN060ATGMwith ducted air handler OTA18C006A | TGM | 4 tons47,000 Btu/h · Ducted | 2.30 | 72% | 9.2 | 18.5 | 11.5 | 34,000 | CEE 25CEE 26Xcel | 2 | 217747073 |
| 6038TMRHT18AS2TGM | TGM | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 78% | 10.0 | 25.0 | 11.7 | 14,000 | CEE 25CEE 26Xcel | 2 | 218787805 |
| 6039TMRHT27AS3TGM | TGM | 2.5 tons28,000 Btu/h · Ducted and non-ducted | 2.00 | 75% | 10.0 | 22.0 | 11.2 | 21,000 | CEE 25CEE 26Xcel | 2 | 218787806 |
| 6040TMRHT36AS4TGM | TGM | 3 tons38,000 Btu/h · Ducted and non-ducted | 2.00 | 74% | 10.0 | 23.0 | 11.2 | 31,000 | CEE 25CEE 26Xcel | 2 | 218787807 |
| 6041TMRHT42AS5TGM | TGM | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.00 | 74% | 10.0 | 24.0 | 11.2 | 31,000 | CEE 25CEE 26Xcel | 2 | 218787808 |
| 6042TSZRHT09ASTGMwith ductless indoor unit TC4VHT09S | TGM | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 83% | 10.0 | 23.0 | 12.5 | 7,500 | CEE 25CEE 26Xcel | 3 | 218787813 |
| 6043TSZRHT12ASTGMwith ductless indoor unit TC4VHT12S | TGM | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 71% | 9.5 | 21.0 | 10.5 | 8,500 | CEE 25CEE 26Xcel | 3 | 218787814 |
| 6044TSZRHT24ASTGMwith ductless indoor unit TC4VHT24S | TGM | 2 tons24,000 Btu/h · Non-ducted | 1.90 | 71% | 9.5 | 18.0 | 11.0 | 17,000 | CEE 25CEE 26Xcel | 4 | 218787816 |
| 6045THP-GUD18W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD18AH2/E-D(U) | The Heat Pump | 1.5 tons18,000 Btu/h · Ducted | 2.00 | 100% | 9.0 | 18.0 | 12.5 | 18,000 | CEE 25CEE 26XcelES CC | 1 | 218338354 |
| 6046THP-GUD36W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD24AH2/G-D(U) | The Heat Pump | 2 tons24,000 Btu/h · Ducted | 2.00 | 96% | 10.0 | 18.0 | 12.5 | 24,000 | CEE 25CEE 26XcelES CC | 4 | 218338357 |
| 6047THP-GUD60W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD60AH2/G-D(U) | The Heat Pump | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | 11.5 | 54,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 218338362 |
| 6048TZID18H520ZCSTHERMAL ZONE · TZID Serieswith ducted air handler TZID18H520ZAM | THERMAL ZONE | 1.5 tons18,000 Btu/h · Ducted | 2.00 | 62% | 9.1 | 18.8 | 11.0 | 11,200 | CEE 25CEE 26 | 12 | 218043392 |
| 6049TZID24H520ZCSTHERMAL ZONE · TZID Serieswith ducted air handler TZID24H520ZAM | THERMAL ZONE | 2 tons24,000 Btu/h · Ducted | 1.87 | 83% | 9.7 | 18.1 | 11.0 | 21,600 | CEE 25CEE 26XcelES CC | 12 | 218043394 |
| 6050TZID36H520ZCThermal Zone · TZID36H520ZCwith ducted air handler TZID24H520ZA | THERMAL ZONE | 2 tons24,000 Btu/h · Ducted | 2.10 | 83% | 9.4 | 20.0 | 13.3 | 20,000 | CEE 25CEE 26XcelES CC | 3 | 217495954 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,851 models; narrow the filters for the rest.