Skip to content

The Heat Pump heat pump efficiency: 3 outdoor models compared

The Heat Pump has 3 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes The Heat Pump makes. The Heat Pump has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
3
AHRI certifications
9
Efficiency index
72%
Typical model vs same-size, same-type peers (3 models)
Meet CEE 2025
100%
3 models

How The Heat Pump compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
The Heat Pump against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of The Heat Pump’s own modelsThe Heat Pump is strongest on heating capacity at 5°F (its typical model beats 93% of comparable models) and weakest on COP at 5°F (61%).
  • The Heat Pump
  • Middle half of its models
  • Other ranked manufacturers
The Heat…

Source: AHRI Directory, NEEP · as of

Average peer percentile of The Heat Pump’s models
RatingBeats comparable modelsRankRaw median
Efficiency index3 models scored72%Not ranked—
COP at 5°F3 models scored61%Not ranked2.00
Capacity retention at 5°F3 models scored92%Not ranked100%
HSPF23 models scored69%Not ranked10.0
SEER23 models scored66%Not ranked18.0
EER23 models scored76%Not ranked12.5
Heating capacity at 5°F3 models scored93%Not ranked24,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
The Heat Pump’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • The Heat Pump (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 3.5–4.5 tons2.002,224 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons166%63%33%60%
Ducted, 2 tons172%51%85%55%
Ducted, 3.5–4.5 tons179%69%91%82%

Every The Heat Pump model in the market

The Heat Pump’s 3 models with a known size and duct type, over the shape of the whole catalog.
The Heat Pump models by size and ratingColoured: The Heat Pump · grey shapes: all 14,508 models · lines: catalog medians by size
  • The Heat Pump models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 3 the heat pump models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top The Heat Pump models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 The Heat Pump cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1THP-GUD60W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD60AH2/G-D(U)4.5 tons53,000 Btu/h · Ducted100%2.1010.554,00018.5CEE 25CEE 26CEE AdvXcelDOEES CC4218338362Ducted, 3.5–4.5 tons85.1
2THP-GUD36W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD36AH2/G-D(U)3 tons34,000 Btu/h · Ducted100%2.0010.034,00018.2CEE 25CEE 26XcelES CC4218338358Ducted, 2 tons76.9
3THP-GUD18W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD18AH2/E-D(U)1.5 tons18,000 Btu/h · Ducted100%2.009.018,00018.0CEE 25CEE 26XcelES CC1218338354Ducted, up to 1.5 tons62.5

All-around best

Top 3 The Heat Pump models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1THP-GUD60W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD48AH2/G-D(U)4 tons48,000 Btu/h · Ducted100%2.0010.019.012.0CEE 25CEE 26CEE AdvXcelDOEES CC4218338361Ducted, 3.5–4.5 tons83.178.987.385.1
2THP-GUD36W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD24AH2/G-D(U)2 tons24,000 Btu/h · Ducted96%2.0010.018.012.5CEE 25CEE 26XcelES CC4218338357Ducted, 2 tons72.474.969.976.9
3THP-GUD18W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD18AH2/E-D(U)1.5 tons18,000 Btu/h · Ducted100%2.009.018.012.5CEE 25CEE 26XcelES CC1218338354Ducted, up to 1.5 tons65.862.569.262.5

Best model on each rating

The Heat Pump’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FTHP-GUD60W2/NHE-D(U)2.10Ducted, 3.5–4.5 tons69%218338362
Capacity retention at 5°FTHP-GUD60W2/NHE-D(U)100%Ducted, 3.5–4.5 tons94%218338359
HSPF2THP-GUD60W2/NHE-D(U)10.5Ducted, 3.5–4.5 tons90%218338362
SEER2THP-GUD60W2/NHE-D(U)19.0Ducted, 3.5–4.5 tons85%218338361
EER2THP-GUD60W2/NHE-D(U)12.0Ducted, 3.5–4.5 tons83%218338361
Heating capacity at 5°FTHP-GUD60W2/NHE-D(U)54,000 Btu/hDucted, 3.5–4.5 tons98%218338359

All 3 The Heat Pump models in Explore

The Heat Pump size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
The Heat Pump: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons62.5(50 is the typical model of its size class)THP-GUD18W2/NHE-D(U)with ducted air handler THP-GUD18AH2/E-D(U)1 of 1 models qualify · AHRI 21833835465.8(50 is the typical model of its size class)THP-GUD18W2/NHE-D(U)with ducted air handler THP-GUD18AH2/E-D(U)1 of 1 models have all five ratings · AHRI 218338354
Ducted, 2 tonsNo models in this size class72.4(50 is the typical model of its size class)THP-GUD36W2/NHE-D(U)with ducted air handler THP-GUD24AH2/G-D(U)1 of 1 models have all five ratings · AHRI 218338357
Ducted, 2.5–3 tons76.9(50 is the typical model of its size class)THP-GUD36W2/NHE-D(U)with ducted air handler THP-GUD36AH2/G-D(U)1 of 1 models qualify · AHRI 218338358No models in this size class
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)THP-GUD60W2/NHE-D(U)with ducted air handler THP-GUD60AH2/G-D(U)1 of 1 models qualify · AHRI 21833836283.1(50 is the typical model of its size class)THP-GUD60W2/NHE-D(U)with ducted air handler THP-GUD48AH2/G-D(U)1 of 1 models have all five ratings · AHRI 218338361

All-around board, every manufacturer

Newest The Heat Pump certifications

By AHRI reference number; AHRI issues references in increasing order.
The 3 most recently certified The Heat Pump outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
THP-GUD60W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD60AH2/G-D(U)4.5 tons53,000 Btu/h · Ducted2.10100%10.518.5CEE 25CEE 26CEE AdvXcelDOEES CC4218338362
THP-GUD36W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD36AH2/G-D(U)3 tons34,000 Btu/h · Ducted2.00100%10.018.2CEE 25CEE 26XcelES CC4218338358
THP-GUD18W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD18AH2/E-D(U)1.5 tons18,000 Btu/h · Ducted2.00100%9.018.0CEE 25CEE 26XcelES CC1218338354

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for The Heat Pump in this group.

Compare The Heat Pump

Manufacturers of a similar size, side by side.

The Heat Pump includes these brand names as listed in AHRI: The Heat Pump. Standards are checked against published thresholds; program rules beyond ratings are not checked.