6,512 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6101D5CUHAH24AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons23,600 Btu/h · Ducted | 2.04 | 84% | 9.5 | 17.5 | 11.0 | 19,000 | CEE 25CEE 26XcelES CC | 2 | 218475400 |
| 6102D5CUHAH24AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons23,600 Btu/h · Ducted | 2.04 | 84% | 9.5 | 17.5 | 11.0 | 19,000 | CEE 25CEE 26Xcel | 2 | 217753142 |
| 6103D5CUHAH30AAKViessmann · D5C Serieswith ducted air handler D5MUWAQ30XA3 | Viessmann | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 100% | 10.2 | 17.5 | 11.7 | 32,000 | CEE 25CEE 26XcelES CC | 6 | 218668523 |
| 6104D5CUHAH30AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 2.5 tons31,200 Btu/h · Ducted | 1.92 | 86% | 9.0 | 16.5 | 10.5 | 32,000 | CEE 25CEE 26XcelES CC | 3 | 218492014 |
| 6105D5CUHAH30AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 2.5 tons31,200 Btu/h · Ducted | 1.92 | 86% | 9.0 | 16.5 | 10.5 | 32,000 | CEE 25CEE 26Xcel | 3 | 217753146 |
| 6106D5CUHAH36AAKViessmann · D5C Serieswith ducted air handler D5FUAAH36XAK | Viessmann | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | 11.7 | 39,000 | CEE 25CEE 26XcelES CC | 9 | 217178767 |
| 6107D5CUHAH36AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26XcelES CC | 2 | 218496432 |
| 6108D5CUHAH36AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26Xcel | 2 | 217753148 |
| 6109D5CUHAH48AAKViessmann · D5C Serieswith ducted air handler D5FUHAH60XAK | Viessmann | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 9.5 | 17.5 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 4 | 217178774 |
| 6110D5CUHAH60AAKViessmann · D5C Serieswith ducted air handler D5FUHAH60XAK | Viessmann | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | 12.0 | 54,000 | CEE 25CEE 26XcelES CC | 6 | 217178771 |
| 6111D5CUHAH60AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5B60L0D | Viessmann | 4.5 tons54,500 Btu/h · Ducted | 1.84 | 88% | 9.0 | 16.0 | 10.0 | 52,000 | CEE 25CEE 26Xcel | 1 | 217753140 |
| 6112D5CURAH24AAKVIESSMANN · Crossover heat pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons24,000 Btu/h · Ducted | 1.98 | 81% | 9.0 | 15.5 | 10.0 | 19,500 | CEE 25CEE 26XcelES CC | 8 | 217753132 |
| 6113D5CURAH24AAK+KSAIC0701230VIESSMANN · Crossover heat pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons24,000 Btu/h · Ducted | 1.98 | 81% | 9.0 | 15.5 | 10.0 | 19,500 | CEE 25CEE 26XcelES CC | 2 | 218475424 |
| 6114D5CURAH36AAKVIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons37,400 Btu/h · Ducted | 2.24 | 64% | 8.5 | 16.0 | 9.0 | 24,400 | CEE 25CEE 26XcelES CC | 10 | 217753153 |
| 6115D5CURAH48AAKViessmann · D5C Serieswith ducted air handler D5FUAAH48XAK | Viessmann | 4 tons48,000 Btu/h · Ducted | 1.85 | 79% | 8.5 | 16.0 | 10.0 | 38,000 | CEE 25CEE 26XcelES CC | 4 | 217178779 |
| 6116VHP-UCHA-24HDCTVillarawith ducted air handler VAH-UCHA-24HDC | Villara | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | 14.0 | 17,800 | CEE 25CEE 26Xcel | 1 | 217081897 |
| 6117VHP-UCHA-36HDCTVillara · T Serieswith ducted air handler VAH-UCHA-36HDC | Villara | 3 tons34,200 Btu/h · Ducted | 2.20 | 73% | 9.0 | 18.5 | 11.3 | 25,000 | CEE 25CEE 26Xcel | 1 | 217001204 |
| 6118VHP-UCHA-48HDCTVillarawith ducted air handler VAH-UCHA-48HDC | Villara | 4 tons48,000 Btu/h · Ducted | 2.20 | 73% | 9.8 | 18.5 | 11.0 | 35,000 | CEE 25CEE 26Xcel | 1 | 217081898 |
| 6119VHP-UCA-24HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-24HDC-A | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | 14.0 | 17,800 | CEE 25CEE 26XcelES CC | 1 | 218030989 |
| 6120VHP-UCA-36HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-36HDC-A | VillaTherm | 3 tons34,200 Btu/h · Ducted | 2.20 | 73% | 9.0 | 18.5 | 11.3 | 25,000 | CEE 25CEE 26XcelES CC | 1 | 218030990 |
| 6121VHP-UCA-48HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-48HDC-A | VillaTherm | 4 tons48,000 Btu/h · Ducted | 2.20 | 73% | 9.8 | 18.5 | 11.0 | 35,000 | CEE 25CEE 26XcelES CC | 1 | 218030991 |
| 6122VHP-UCHA-24HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-24HDCSN4 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | 12.0 | 24,000 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217753628 |
| 6123VHP-UCHA-24HDCTVillaTherm · T Serieswith ducted air handler VAH-UCHA-24HDC | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | 14.0 | 17,800 | CEE 25CEE 26XcelES CC | 1 | 217155424 |
| 6124VHP-UCHA-24HDCT-AVillaTherm · SPLIT AHUwith ducted air handler VAH-UCHA-24SHDCALN2 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.30 | 100% | 10.2 | 19.0 | 12.5 | 24,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 218696917 |
| 6125VHP-UCHA-36HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-36HDCSN4 | VillaTherm | 3 tons34,200 Btu/h · Ducted | 2.10 | 76% | 9.0 | 18.0 | 11.0 | 26,000 | CEE 25CEE 26Xcel | 1 | 217753629 |