Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

7,174 models

Sorted by manufacturer and model.
Page 31 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
751BNG3Z60UCNBLUERIDGE · NG3with ducted air handler BNGFZ60DH0BlueRidge4.5 tons53,000 Btu/h · Ducted2.10100%10.018.211.254,000CEE 25CEE 26CEE AdvXcelDOEES CC2218043777
752BXL1A36SC0BLUERIDGE · BXL Serieswith ductless indoor unit BXALA36CC4BlueRidge3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.09.626,600CEE 25CEE 26XcelES CC3216997575
753BXL1A48SC0BLUERIDGE · BXL Serieswith ductless indoor unit BXALA48CC4BlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.09.540,500CEE 25CEE 26XcelES CC3216997576
754BXL2A36UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA36CDHBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.712.037,600CEE 25CEE 26XcelES CC3216997585
755BXL2A48UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA48CDHBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.0091%10.816.710.447,500CEE 25CEE 26XcelES CC3216997586
756BXL2A60UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA60CDHBlueRidge4.5 tons55,000 Btu/h · Ducted and non-ducted2.1089%10.415.810.253,500XcelES CC2216997587
757BXM0Z18SC0BLUERIDGE · Multi R32 AOBlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%8.517.011.313,800CEE 25CEE 26XcelES CC3218405544
758BXM0Z24SC0BLUERIDGE · Multi R32 AOBlueRidge2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0071%8.517.011.617,000CEE 25CEE 26XcelES CC3218405545
759BXM0Z30SC0BLUERIDGE · Multi R32 AOBlueRidge2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9070%8.517.011.121,000CEE 25CEE 26XcelES CC3218405556
760BXM0Z36SC0BLUERIDGE · Multi R32 AOBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8078%8.517.011.628,000CEE 25CEE 26XcelES CC3218471016
761BXM0Z42SC0BLUERIDGE · Multi R32 AOBlueRidge3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8070%8.517.011.029,400CEE 25CEE 26XcelES CC3218405547
762BXM1A18SC0BLUERIDGE · BXM SeriesBlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3216997604
763BXM1A27SC0BLUERIDGE · BXM SeriesBlueRidge2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3216997605
764BXM1A36SC0BLUERIDGE · BXM SeriesBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3216997608
765BXM1A48SC0BLUERIDGE · BXM SeriesBlueRidge4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.412.038,000CEE 25CEE 26XcelES CC3216997612
766BXM2Z18UC0BLUERIDGE · XS4BlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%10.021.012.013,800CEE 25CEE 26XcelES CC3217448533
767BXM2Z24UC0BLUERIDGE · XS4BlueRidge2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.013.321,600CEE 25CEE 26XcelES CC3217448534
768BXM2Z30UC0BLUERIDGE · XS4BlueRidge2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0790%10.021.013.627,000CEE 25CEE 26XcelES CC3217448535
769BXM2Z36UC0BLUERIDGE · XS4BlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.021.012.036,000CEE 25CEE 26CEE AdvXcelDOEES CC3217448536
770BXM2Z42UC0BLUERIDGE · XS4BlueRidge3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.013.037,800CEE 25CEE 26XcelES CC3217448537
771BXM2Z48UC0BLUERIDGE · XS4with ductless indoor unit BGS926UHYW+BGS926UHYW+BGS926UHYW+BGS926UHYW+BGS926UHYWBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1079%10.021.012.037,800CEE 25CEE 26XcelES CC3217500176
772BXM3A18UC0BLUERIDGE · BXM SeriesBlueRidge1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3216997617
773BXM3A27UC0BLUERIDGE · BXM SeriesBlueRidge2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3216997620
774BXM3A36UC0BLUERIDGE · BXM SeriesBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3216997623
775BXM3A48UC0BLUERIDGE · BXM SeriesBlueRidge4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.012.047,000CEE 25CEE 26XcelES CC3216997626

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,174 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter