Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,326 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 9651ML48HP230LCM-OMAINLINE · ML Serieswith ductless indoor unit ML48HP230STDCAS-I | Rheem | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | 9.5 | 40,500 | CEE 25CEE 26XcelES CC | 8 | 215864391 |
| 9652ML48HP230LCMH-OMAINLINE · ML Serieswith ducted air handler ML48HP230RS485AHU-I | Rheem | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.00 | 92% | 10.2 | 17.0 | 10.0 | 46,000 | CEE 25CEE 26XcelES CC | 8 | 215864302 |
| 9653ML48HP230LMNT-OMAINLINE · ML Serieswith ducted air handler ML48HP230LMNTAHU-I | Rheem | 4 tons48,000 Btu/h · Ducted | 1.85 | 79% | 8.5 | 16.0 | 10.0 | 38,000 | CEE 25CEE 26XcelES CC | 10 | 215864308 |
| 9654ML48HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML48HP230G3AHU-I | Rheem | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 9.5 | 17.5 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 16 | 216623403 |
| 9655ML48HP230MUL-OMAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 75% | 10.0 | 21.3 | 11.7 | 36,000 | CEE 25CEE 26XcelES CC | 6 | 215864415 |
| 9656ML48HP230MUL-O*MAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 81% | 10.6 | 20.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 216623563 |
| 9657ML48HP230MULH-OMAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 98% | 10.2 | 21.2 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 6 | 215864430 |
| 9658ML48HP230MULH-O*MAINLINE · ML Series | Rheem | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | 12.0 | 47,000 | CEE 25CEE 26XcelES CC | 3 | 216623574 |
| 9659ML50HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML50HP230LMNTAHU-I | Rheem | 4 tons48,000 Btu/h · Ducted | 1.80 | 93% | 9.0 | 16.3 | 11.7 | 52,000 | CEE 25CEE 26XcelES CC | 2 | 215864317 |
| 9660ML55HP230MUL-OMAINLINE | Rheem | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 67% | 9.2 | 18.0 | 10.0 | 40,000 | CEE 25CEE 26 | 3 | 215864419 |
| 9661ML55HP230MUL-O*MAINLINE | Rheem | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 65% | 9.5 | 22.0 | 10.0 | 39,000 | CEE 25CEE 26 | 3 | 216623550 |
| 9662ML55HP230MULH-OMAINLINE · ML Series | Rheem | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 6 | 215864434 |
| 9663ML55HP230MULH-O*MAINLINE · ML Series | Rheem | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 216623578 |
| 9664ML60HP230LCM-OMAINLINEwith ducted air handler ML60HP230HSDUC-I | Rheem | 5 tons58,000 Btu/h · Ducted and non-ducted | 2.20 | 67% | 9.7 | 17.0 | 10.0 | 40,000 | CEE 25CEE 26 | 3 | 215864394 |
| 9665ML60HP230LCMH-OMAINLINE · ML Serieswith ducted air handler ML60HP230HSDUC-I | Rheem | 4.5 tons55,000 Btu/h · Ducted and non-ducted | 2.10 | 89% | 10.4 | 15.8 | 10.2 | 53,500 | XcelES CC | 6 | 215864402 |
| 9666ML60HP230LMNT-OMAINLINE · ML Serieswith ducted air handler ML60HP230LMNTAHU-I | Rheem | 4.5 tons54,000 Btu/h · Ducted | 1.80 | 70% | 8.4 | 15.2 | 8.6 | 38,000 | ES CC | 6 | 215864309 |
| 9667ML60HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML60HP230G3AHU-I | Rheem | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | 12.0 | 54,000 | CEE 25CEE 26XcelES CC | 12 | 216623404 |
| 9668MLP14AY18AJ1NMAINLINEwith ducted air handler MLH2CY2417STANN | Rheem | 1.5 tons17,100 Btu/h · Ducted | 1.80 | 51% | 7.5 | 14.3 | 9.0 | 8,600 | None | 39 | 214575756 |
| 9669MLP14AY24AJ2NMAINLINEwith ducted air handler RF2TY2421STANS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.00 | 46% | 7.5 | 14.3 | 9.0 | 10,500 | None | 42 | 216687472 |
| 9670MLP14AY30AJ2NMAINLINEwith ducted air handler 31HXX | Rheem | 2.5 tons28,000 Btu/h · Ducted | 1.94 | 49% | 7.5 | 14.3 | 9.0 | 13,300 | None | 181 | 217598634 |
| 9671MLP14AY36AC2NMAINLINEwith ducted air handler MLH2CY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687480 |
| 9672MLP14AY36AD2NMAINLINEwith ducted air handler MLH2CY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687483 |
| 9673MLP14AY36AJ2NMAINLINEwith ducted air handler MLH2CY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | 2.10 | 53% | 7.5 | 14.3 | 9.0 | 17,400 | None | 182 | 214575750 |
| 9674MLP14AY42AC2NMAINLINEwith ducted air handler MLH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687478 |
| 9675MLP14AY42AD2NMAINLINEwith ducted air handler MLH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687479 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,326 models; narrow the filters for the rest.