- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,332 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 110015A6H4030A1AMERICAN STANDARDwith indoor coil DH36T4J and furnace L8X1B060U3XSA | Trane | 2 tons26,200 Btu/h · Ducted | 2.77 | 68% | 7.5 | 14.3 | 11.7 | 17,000 | None | 1,096 | 217146884 |
| 110025A6H4036A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace *UHMC100CCV4 | Trane | 2.5 tons32,800 Btu/h · Ducted | 3.18 | 72% | 7.5 | 14.3 | 11.7 | 22,000 | None | 1,445 | 217147162 |
| 110035A6H4042A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8V2C100M5PCB | Trane | 3 tons36,000 Btu/h · Ducted | 2.83 | 63% | 7.5 | 14.3 | 11.7 | 24,600 | None | 1,170 | 217147575 |
| 110045A6H4048A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8V2B060M4PCB | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.75 | 67% | 7.5 | 14.3 | 11.7 | 29,400 | None | 921 | 217147707 |
| 110055A6H4060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8X1D120M5PSC | Trane | 4.5 tons52,000 Btu/h · Ducted | 3.08 | 69% | 7.5 | 14.3 | 11.0 | 36,000 | None | 393 | 217147816 |
| 110065A6H5018A1AMERICAN STANDARDwith indoor coil D(A,C,E)30A3J+TDR and furnace S9V2B060U3VSA | Trane | 1.5 tons16,600 Btu/h · Ducted | 2.60 | 64% | 7.5 | 14.8 | 11.2 | 11,200 | CEE 25CEE 26 | 714 | 217084597 |
| 110075A6H5024A1AMERICAN STANDARDwith indoor coil D(A,C,E)36C3J+TDR and furnace S9V2B080D4PSC | Trane | 2 tons21,000 Btu/h · Ducted | 2.82 | 67% | 8.5 | 15.2 | 11.2 | 14,400 | CEE 25CEE 26 | 1,726 | 217084932 |
| 110085A6H5030A1AMERICAN STANDARDwith indoor coil DH30T3J and furnace S8V2C100M5PCB | Trane | 2 tons26,800 Btu/h · Ducted | 2.82 | 67% | 8.2 | 15.9 | 11.8 | 17,000 | CEE 25CEE 26 | 2,081 | 217148366 |
| 110095A6H5036A1AMERICAN STANDARDwith indoor coil DH36T4J and furnace S9V2C100U5PSC | Trane | 3 tons33,600 Btu/h · Ducted | 3.19 | 70% | 9.0 | 16.3 | 12.0 | 22,200 | CEE 25CEE 26Xcel | 1,625 | 217149038 |
| 110105A6H5042A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace L8V1B080U4VSB | Trane | 3 tons36,000 Btu/h · Ducted | 2.84 | 64% | 8.2 | 15.5 | 12.4 | 25,400 | CEE 25CEE 26 | 2,342 | 217149166 |
| 110115A6H5048A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S9V2D120D5PSC | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.77 | 67% | 7.7 | 15.4 | 12.0 | 28,400 | CEE 25CEE 26 | 1,358 | 217149511 |
| 110125A6H5060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace L8V1C100U5VSB | Trane | 4.5 tons52,500 Btu/h · Ducted | 3.05 | 70% | 8.1 | 15.4 | 11.7 | 36,600 | Xcel | 643 | 217149553 |
| 110135A6H6018A1AMERICAN STANDARDwith ducted air handler L(E,F)W36DJ | Trane | 1.5 tons18,000 Btu/h · Ducted | 2.59 | 60% | 7.9 | 15.2 | 11.7 | 10,600 | CEE 25 | 353 | 218378508 |
| 110145A6H6024A1AMERICAN STANDARDwith ducted air handler L(E,F)W36DJ | Trane | 2 tons22,400 Btu/h · Ducted | 2.49 | 62% | 7.8 | 15.2 | 12.0 | 13,400 | CEE 25CEE 26 | 483 | 218378511 |
| 110155A6H6030A1AMERICAN STANDARDwith ducted air handler L(E,F)W30EJ | Trane | 2 tons24,800 Btu/h · Ducted | 2.63 | 66% | 7.5 | 14.8 | 11.2 | 16,400 | CEE 25CEE 26 | 641 | 218378512 |
| 110165A6H6036A1AMERICAN STANDARDwith ducted air handler L(E,F)W36DJ | Trane | 2.5 tons29,600 Btu/h · Ducted | 2.78 | 69% | 7.8 | 14.8 | 11.7 | 20,800 | CEE 25CEE 26 | 714 | 218378516 |
| 110175A6H6042A1AMERICAN STANDARDwith ducted air handler 97-985+TXV+RDS+TDR+E30B5D | Trane | 3 tons38,000 Btu/h · Ducted | 2.50 | 49% | 7.8 | 15.2 | 12.0 | 17,900 | CEE 25CEE 26 | 449 | 218737044 |
| 110185A6H6048A1AMERICAN STANDARDwith ducted air handler 98-887+TXV+RDS+TDR+E30B5D | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.34 | 52% | 7.8 | 15.2 | 12.0 | 21,200 | CEE 25CEE 26 | 551 | 218737043 |
| 110195A6H6060A1AMERICAN STANDARDwith ducted air handler 98-8812+TXV+RDS+TDR+E30B6D | Trane | 4.5 tons52,000 Btu/h · Ducted | 2.60 | 55% | 7.8 | 15.0 | 11.5 | 27,400 | None | 303 | 218687400 |
| 110205A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDR | Trane | 2 tons21,000 Btu/h · Ducted | 2.87 | 111% | 8.1 | 15.5 | 11.7 | 24,400 | CEE 25CEE 26XcelES CC | 731 | 217155223 |
| 110215A6H7036A1AMERICAN STANDARDwith ducted air handler D(A,C,E)36B4J+TDR | Trane | 2.5 tons31,200 Btu/h · Ducted | 2.97 | 134% | 7.8 | 15.5 | 11.2 | 43,500 | CEE 25CEE 26XcelES CC | 1,188 | 217117484 |
| 110225A6H7048A1AMERICAN STANDARDwith ducted air handler AE*L+CM48B3J+TDR | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.74 | 64% | 8.5 | 16.0 | 11.2 | 27,600 | CEE 25CEE 26XcelES CC | 668 | 217155229 |
| 110235A6H7060A1AMERICAN STANDARDwith ducted air handler D(A,C,E)60B4J+TDR | Trane | 4 tons49,500 Btu/h · Ducted | 2.92 | 62% | 7.8 | 15.2 | 10.5 | 33,400 | CEE 25CEE 26XcelES CC | 422 | 217117491 |
| 110245A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRP | Trane | 1.5 tons19,500 Btu/h · Ducted | 2.93 | 98% | 10.0 | 21.0 | 11.2 | 21,800 | CEE 25CEE 26XcelES CC | 167 | 217117128 |
| 110255A6V0X36A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD06AV41+TDR | Trane | 3 tons36,200 Btu/h · Ducted | 2.30 | 66% | 10.5 | 21.6 | 13.0 | 25,400 | CEE 25CEE 26XcelES CC | 136 | 217734495 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,332 models; narrow the filters for the rest.