Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

13,619 models

Sorted by manufacturer and model.
Page 57 of 545
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1401BRP7HP1348EP-*BLUERIDGEBlueRidge4 tons45,500 Btu/h · Ducted1.5037%6.713.410.617,400None1216799819
1402BRP7HP1360EP-*BLUERIDGEBlueRidge4.5 tons56,000 Btu/h · Ducted1.8025%6.713.410.614,000None1216799820
1403BXL1A36SC0BLUERIDGE · BXL Serieswith ductless indoor unit BXALA36CC4BlueRidge3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.09.626,600CEE 25CEE 26XcelES CC3216997575
1404BXL1A48SC0BLUERIDGE · BXL Serieswith ductless indoor unit BXALA48CC4BlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.09.540,500CEE 25CEE 26XcelES CC3216997576
1405BXL1A60SC0BLUERIDGEwith ducted air handler BXALA60CDHBlueRidge5 tons58,000 Btu/h · Ducted and non-ducted2.2067%9.717.010.040,000CEE 25CEE 262216997579
1406BXL2A36UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA36CDHBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.712.037,600CEE 25CEE 26XcelES CC3216997585
1407BXL2A48UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA48CDHBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.0091%10.816.710.447,500CEE 25CEE 26XcelES CC3216997586
1408BXL2A60UC0BLUERIDGE · BXL Serieswith ducted air handler BXALA60CDHBlueRidge4.5 tons55,000 Btu/h · Ducted and non-ducted2.1089%10.415.810.253,500XcelES CC2216997587
1409BXM0Z18SC0BLUERIDGE · Multi R32 AOBlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%8.517.011.313,800CEE 25CEE 26XcelES CC3218405544
1410BXM0Z24SC0BLUERIDGE · Multi R32 AOBlueRidge2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0071%8.517.011.617,000CEE 25CEE 26XcelES CC3218405545
1411BXM0Z30SC0BLUERIDGE · Multi R32 AOBlueRidge2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9070%8.517.011.121,000CEE 25CEE 26XcelES CC3218405556
1412BXM0Z36SC0BLUERIDGE · Multi R32 AOBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8078%8.517.011.628,000CEE 25CEE 26XcelES CC3218471016
1413BXM0Z42SC0BLUERIDGE · Multi R32 AOBlueRidge3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8070%8.517.011.029,400CEE 25CEE 26XcelES CC3218405547
1414BXM1A18SC0BLUERIDGE · BXM SeriesBlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3216997604
1415BXM1A27SC0BLUERIDGE · BXM SeriesBlueRidge2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3216997605
1416BXM1A36SC0BLUERIDGE · BXM SeriesBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3216997608
1417BXM1A48SC0BLUERIDGE · BXM SeriesBlueRidge4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.412.038,000CEE 25CEE 26XcelES CC3216997612
1418BXM1A60SC0BLUERIDGEBlueRidge5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2065%9.522.010.039,000CEE 25CEE 263216997614
1419BXM2Z18UC0BLUERIDGE · XS4BlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%10.021.012.013,800CEE 25CEE 26XcelES CC3217448533
1420BXM2Z24UC0BLUERIDGE · XS4BlueRidge2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.013.321,600CEE 25CEE 26XcelES CC3217448534
1421BXM2Z30UC0BLUERIDGE · XS4BlueRidge2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0790%10.021.013.627,000CEE 25CEE 26XcelES CC3217448535
1422BXM2Z36UC0BLUERIDGE · XS4BlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.021.012.036,000CEE 25CEE 26CEE AdvXcelDOEES CC3217448536
1423BXM2Z42UC0BLUERIDGE · XS4BlueRidge3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.013.037,800CEE 25CEE 26XcelES CC3217448537
1424BXM2Z48UC0BLUERIDGE · XS4with ductless indoor unit BGS926UHYW+BGS926UHYW+BGS926UHYW+BGS926UHYW+BGS926UHYWBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1079%10.021.012.037,800CEE 25CEE 26XcelES CC3217500176
1425BXM2Z55UC0BLUERIDGE · XM2BlueRidge4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9066%10.021.011.736,400CEE 25CEE 263218330407

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter