Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

2,942 models

Sorted by manufacturer and model.
Page 95 of 118
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2351RHPXYB036AJTRUSSELLRUSSELL3 tons34,200 Btu/h · Ducted1.5138%6.713.410.612,800None1215876700
2352RHPXYC036ACTRUSSELLRUSSELL3 tons34,200 Btu/h · Ducted1.8040%7.215.211.513,800None1216437534
2353RHPXYC036ADTRUSSELLRUSSELL3 tons34,200 Btu/h · Ducted1.8040%7.215.211.513,800None1216437538
2354RHPXYC036AJTRUSSELL · RHPXYCRUSSELL3 tons34,200 Btu/h · Ducted1.8040%7.215.211.513,800None1216437542
2355SP14AY30AJ2NRUSSELLwith indoor coil TCFY3621STANM and furnace S972V0855A21UPSRUSSELL2.5 tons28,400 Btu/h · Ducted2.0049%7.514.810.513,900None68218696001
2356SP14AY36AC2NRUSSELLwith ducted air handler SH2CY3617STANNRUSSELL3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011635
2357SP14AY36AD2NRUSSELLwith ducted air handler SH2CY3617STANNRUSSELL3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011638
2358SP14AY36AJ2NRUSSELLwith ducted air handler SH2CY3617STANNRUSSELL3 tons34,200 Btu/h · Ducted2.1053%7.514.39.017,400None95214568802
2359SP15AY30AJ2NRUSSELL · VANTIXwith ducted air handler SH2CY3617STANNRUSSELL2.5 tons28,400 Btu/h · Ducted2.0051%7.815.211.714,600None81215487013
2360SP15AY36AC2NRUSSELLwith ducted air handler SH2CY3617STANNRUSSELL3 tons34,200 Btu/h · Ducted——7.514.39.0—None1216011708
2361SP15AY36AD2NRUSSELLwith ducted air handler SH2CY3617STANNRUSSELL3 tons34,200 Btu/h · Ducted——7.514.39.0—None2216011709
2362SP15AY36AJ2NRUSSELL · VANTIXwith ducted air handler SH2VY3621STACNRUSSELL3 tons34,200 Btu/h · Ducted2.1052%7.816.012.017,800None86216030766
2363SP19AY36AJVCRUSSELL · VANTIXwith indoor coil TCFY3621MEAAM and furnace S972V0603A17UPSRUSSELL3 tons34,200 Btu/h · Ducted2.2077%8.520.012.026,200CEE 25CEE 26XcelES CC19218728679
2364AC030DXADCGSAMSUNG · 4-Way Cassette (WindFree™) Standard (CAC)with ductless indoor unit AC030DN4DCGSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.8080%9.521.712.027,200CEE 25CEE 26XcelES CC3215490144
2365AC030DXSCCGSAMSUNG · 4-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit AC030DN4DCGNot ranked: cold-weather ratings look inconsistent.Samsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.80100%10.722.814.434,000CEE 25CEE 26XcelES CC5215385454
2366AC036DXADCGSAMSUNG · 4-Way Cassette (WindFree™) Standard (CAC)with ductless indoor unit AC036DN4DCGSamsung3 tons36,000 Btu/h · Ducted and non-ducted1.8080%9.219.511.032,000CEE 25CEE 26XcelES CC3215490145
2367AC036DXSCCGSAMSUNG · 4-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit AC036DN4DCGNot ranked: cold-weather ratings look inconsistent.Samsung3 tons36,000 Btu/h · Ducted and non-ducted1.80100%10.622.013.540,000CEE 25CEE 26XcelES CC5215385457
2368AC036FCUDCGSAMSUNGwith ducted air handler L(E,G)M36FJSamsung2.5 tons31,800 Btu/h · Ducted2.4459%7.814.59.020,400XcelES CC52218159534
2369AC036FCUPCGSAMSUNGwith ducted air handler L(E,G)M36FJSamsung3 tons36,000 Btu/h · Ducted2.5763%8.517.012.022,200CEE 25CEE 26XcelES CC62218159535
2370AJ030DXS4CGSAMSUNG · FJM (Premium)Samsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.81100%10.022.513.528,600CEE 25CEE 26XcelES CC3216372793
2371AJ036DXJ4CGSAMSUNG · FJM (Standard)Samsung2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8173%9.522.512.526,400CEE 25CEE 26Xcel3216372789
2372AJ036DXS4CGSAMSUNG · FJM (Premium)Samsung3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.04100%9.521.512.536,600CEE 25CEE 26XcelES CC3216372792
2373AM036FCMDCGSAMSUNG · DVM S MiniSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1279%11.022.013.533,210CEE 25CEE 26XcelES CC3216032693
2374AM036HCMDCSSAMSUNG · DVM S MiniSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1279%11.022.013.533,210CEE 25CEE 26XcelES CC3218399249
2375AR36DXFUMGMXSAMSUNG · High-Wall (RAC)with ductless indoor unit AR36DXFUMGMNSamsung3 tons33,000 Btu/h · Non-ducted1.8090%9.020.012.036,000CEE 25CEE 26XcelES CC1216741657