Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
A/H EDEN vs HOMCOM heat pumps
Measured against models of the same size and duct type, HOMCOM scores higher on 5 of the 6 ratings. A/H EDEN has 7 outdoor models, HOMCOM has 7 outdoor models. A/H EDEN and HOMCOM have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- A/H EDEN
- HOMCOM
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | A/H EDEN | HOMCOM |
|---|---|---|
| Efficiency index | 34%median — | 45%median — |
| COP at 5°F | 43%median 1.90 | 70%median 2.09 |
| Capacity retention at 5°F | 31%median 73% | 41%median 75% |
| HSPF2 | 45% (higher)median 9.5 | 37% (higher)median 9.0 |
| SEER2 | 31%median 20.0 | 46%median 22.0 |
| EER2 | 26%median 10.5 | 33%median 11.0 |
| Heating capacity at 5°F | 33%median 9,000 Btu/h | 48%median 12,600 Btu/h |
| Outdoor models | 7 | 7 |
| AHRI certifications | 7 | 7 |
Share of models meeting each standard
| Standard | A/H EDEN | HOMCOM |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7%6 models | 85.7%6 models |
| CEE 2026 Tier 1 (Split ASHP) | 85.7%6 models | 85.7%6 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1%4 models | 71.4%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 42.9%3 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- A/H EDEN
- HOMCOM
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | A/H EDEN | HOMCOM |
|---|---|---|
| Non-ducted, up to 1.5 tons | 5 · index 35% | 5 · index 44% |
| Non-ducted, 2 tons | 1 · index 39% | 2 · index 46% |
| Non-ducted, 2.5–3 tons | 1 · index 23% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | A/H EDENCold-climate score, best model | HOMCOMCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 50.4(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE4 of 5 models qualify · AHRI 217513412 | 59.7(50 is the typical model of its size class) (higher)823-093V82WTwith ductless indoor unit 823-091V82WT4 of 5 models qualify · AHRI 218158847 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 77.2(50 is the typical model of its size class)823-093V83WTwith ductless indoor unit 823-091V83WT1 of 2 models qualify · AHRI 218158848 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | A/H EDENAll-around score, best model | HOMCOMAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 43.9(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE5 of 5 models have all five ratings · AHRI 217513412 | 55.3(50 is the typical model of its size class) (higher)823-093V82WTwith ductless indoor unit 823-091V82WT5 of 5 models have all five ratings · AHRI 218158847 |
| Non-ducted, 2 tons | 39.1(50 is the typical model of its size class)AS24HP2AC*with ductless indoor unit AS24HP2AE1 of 1 models have all five ratings · AHRI 217617212 | 68.0(50 is the typical model of its size class) (higher)823-093V83WTwith ductless indoor unit 823-091V83WT2 of 2 models have all five ratings · AHRI 218158848 |
| Non-ducted, 2.5–3 tons | 23.4(50 is the typical model of its size class)AS36HP2AC*with ductless indoor unit AS36HP2AE1 of 1 models have all five ratings · AHRI 217617213 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | A/H EDEN | HOMCOM |
|---|---|---|
| COP at 5°F | beats 88% · 2.10AS36HP2AC*Non-ducted, 2.5–3 tons | beats 85% · 2.20823-093V82WTNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 47% · 75%AS12HP1ACNon-ducted, up to 1.5 tons | beats 75% · 87%823-093V83WTNon-ducted, 2 tons |
| HSPF2 | beats 64% · 10.0AS09HP2ACNon-ducted, up to 1.5 tons | beats 69% · 10.0823-093V83WTNon-ducted, 2 tons |
| SEER2 | beats 47% · 21.0AS24HP2AC*Non-ducted, 2 tons | beats 59% · 22.0823-093V83WTNon-ducted, 2 tons |
| EER2 | beats 44% · 12.0AS09HP2ACNon-ducted, up to 1.5 tons | beats 52% · 12.0823-093V83WTNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 72% · 12,500 Btu/hAS18HP2ACNon-ducted, up to 1.5 tons | beats 77% · 13,500 Btu/h823-093V82WTNon-ducted, up to 1.5 tons |