- Insights
- Manufacturers
- A/H EDEN
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
A/H EDEN heat pump efficiency: 7 outdoor models compared
A/H EDEN has 7 heat pump outdoor models certified with this refrigerant group, in 7 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes A/H EDEN makes. A/H EDEN has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 7
- AHRI certifications
- 7
- Efficiency index
- 34%
- Typical model vs same-size, same-type peers (7 models)
- Meet CEE 2025
- 85.7%
- 6 models
How A/H EDEN compares with comparable models
- A/H EDEN
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index7 models scored | 34% | Not ranked | — |
| COP at 5°F7 models scored | 43% | Not ranked | 1.90 |
| Capacity retention at 5°F7 models scored | 31% | Not ranked | 73% |
| HSPF27 models scored | 45% | Not ranked | 9.5 |
| SEER27 models scored | 31% | Not ranked | 20.0 |
| EER27 models scored | 26% | Not ranked | 10.5 |
| Heating capacity at 5°F7 models scored | 33% | Not ranked | 9,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7% | 6 |
| CEE 2026 Tier 1 (Split ASHP) | 85.7% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- A/H EDEN (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 5 | 35% | 28% | 50% | 31% |
| Non-ducted, 2 tons | 1 | 39% | 71% | 44% | 49% |
| Non-ducted, 2.5–3 tons | 1 | 23% | 88% | 22% | 13% |
Every A/H EDEN model in the market
- A/H EDEN models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top A/H EDEN models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AS09HP2ACA/H EDENwith ductless indoor unit AS09HP2AE | 1 ton9,000 Btu/h · Non-ducted | 74% | 1.90 | 10.0 | 7,400 | 20.0 | CEE 25CEE 26Xcel | 1 | 217513412 | Non-ducted, up to 1.5 tons | 50.4 |
| 2AS09HP1ACA/H EDENwith ductless indoor unit AS09HP1AE | 1 ton9,000 Btu/h · Non-ducted | 73% | 1.90 | 9.5 | 7,300 | 19.0 | CEE 25CEE 26Xcel | 1 | 217513410 | Non-ducted, up to 1.5 tons | 42.5 |
| 3AS12HP1ACA/H EDENwith ductless indoor unit AS12HP1AE | 1 ton12,000 Btu/h · Non-ducted | 75% | 1.80 | 9.5 | 9,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 217513411 | Non-ducted, up to 1.5 tons | 37.6 |
| 4AS12HP2AC*A/H EDENwith ductless indoor unit AS12HP2AE | 1 ton12,000 Btu/h · Non-ducted | 75% | 1.80 | 9.5 | 9,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 217617211 | Non-ducted, up to 1.5 tons | 37.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AS09HP2ACA/H EDENwith ductless indoor unit AS09HP2AE | 1 ton9,000 Btu/h · Non-ducted | 74% | 1.90 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217513412 | Non-ducted, up to 1.5 tons | 43.9 | 50.4 | 37.3 | 50.4 |
| 2AS24HP2AC*A/H EDENwith ductless indoor unit AS24HP2AE | 2 tons24,000 Btu/h · Non-ducted | 65% | 2.10 | 9.5 | 21.0 | 10.5 | CEE 25CEE 26 | 1 | 217617212 | Non-ducted, 2 tons | 39.1 | 43.2 | 35.0 | Not a pick |
| 3AS09HP1ACA/H EDENwith ductless indoor unit AS09HP1AE | 1 ton9,000 Btu/h · Non-ducted | 73% | 1.90 | 9.5 | 19.0 | 11.7 | CEE 25CEE 26Xcel | 1 | 217513410 | Non-ducted, up to 1.5 tons | 35.5 | 42.5 | 28.5 | 42.5 |
| 4AS12HP2AC*A/H EDENwith ductless indoor unit AS12HP2AE | 1 ton12,000 Btu/h · Non-ducted | 75% | 1.80 | 9.5 | 20.0 | 11.2 | CEE 25CEE 26Xcel | 1 | 217617211 | Non-ducted, up to 1.5 tons | 34.0 | 37.6 | 30.4 | 37.6 |
| 5AS12HP1ACA/H EDENwith ductless indoor unit AS12HP1AE | 1 ton12,000 Btu/h · Non-ducted | 75% | 1.80 | 9.5 | 20.0 | 10.5 | CEE 25CEE 26Xcel | 1 | 217513411 | Non-ducted, up to 1.5 tons | 32.2 | 37.6 | 26.7 | 37.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AS36HP2AC* | 2.10 | Non-ducted, 2.5–3 tons | 88% | 217617213 |
| Capacity retention at 5°F | AS12HP1AC | 75% | Non-ducted, up to 1.5 tons | 47% | 217513411 |
| HSPF2 | AS09HP2AC | 10.0 | Non-ducted, up to 1.5 tons | 64% | 217513412 |
| SEER2 | AS24HP2AC* | 21.0 | Non-ducted, 2 tons | 47% | 217617212 |
| EER2 | AS09HP2AC | 12.0 | Non-ducted, up to 1.5 tons | 44% | 217513412 |
| Heating capacity at 5°F | AS18HP2AC | 12,500 Btu/h | Non-ducted, up to 1.5 tons | 72% | 217513413 |
A/H EDEN size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 50.4(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE4 of 5 models qualify · AHRI 217513412 | 43.9(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE5 of 5 models have all five ratings · AHRI 217513412 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 39.1(50 is the typical model of its size class)AS24HP2AC*with ductless indoor unit AS24HP2AE1 of 1 models have all five ratings · AHRI 217617212 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | 23.4(50 is the typical model of its size class)AS36HP2AC*with ductless indoor unit AS36HP2AE1 of 1 models have all five ratings · AHRI 217617213 |
Newest A/H EDEN certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AS36HP2AC*A/H EDENwith ductless indoor unit AS36HP2AE | 3 tons36,000 Btu/h · Non-ducted | 2.10 | 57% | 9.0 | 19.0 | None | 1 | 217617213 |
| AS24HP2AC*A/H EDENwith ductless indoor unit AS24HP2AE | 2 tons24,000 Btu/h · Non-ducted | 2.10 | 65% | 9.5 | 21.0 | CEE 25CEE 26 | 1 | 217617212 |
| AS12HP2AC*A/H EDENwith ductless indoor unit AS12HP2AE | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 75% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 217617211 |
| AS18HP2ACA/H EDENwith ductless indoor unit AS18HP2AE | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 69% | 9.5 | 21.0 | CEE 25CEE 26 | 1 | 217513413 |
| AS09HP2ACA/H EDENwith ductless indoor unit AS09HP2AE | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 74% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 1 | 217513412 |
Compare A/H EDEN
A/H EDEN includes these brand names as listed in AHRI: A/H EDEN. Standards are checked against published thresholds; program rules beyond ratings are not checked.