A/H EDEN vs Badger manufacture heat pumps
Measured against models of the same size and duct type, A/H EDEN scores higher on 2 of the 6 ratings. A/H EDEN has 7 outdoor models, Badger manufacture has 7 outdoor models. A/H EDEN and Badger manufacture have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- A/H EDEN
- Badger manufacture
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | A/H EDEN | Badger manufacture |
|---|---|---|
| Efficiency index | 36%median — | —median — |
| COP at 5°F | 43%median 1.90 | —median — |
| Capacity retention at 5°F | 34%median 73% | —median — |
| HSPF2 | 47% (higher)median 9.5 | 24% (higher)median 7.5 |
| SEER2 | 33% (higher)median 20.0 | 20% (higher)median 14.3 |
| EER2 | 29%median 10.5 | 60%median 11.7 |
| Heating capacity at 5°F | 35%median 9,000 Btu/h | —median — |
| Outdoor models | 7 | 7 |
| AHRI certifications | 7 | 11 |
Share of models meeting each standard
| Standard | A/H EDEN | Badger manufacture |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7%6 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 85.7%6 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1%4 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- A/H EDEN
- Badger manufacture
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | A/H EDEN | Badger manufacture |
|---|---|---|
| Ducted, up to 1.5 tons | None | 1 · index — |
| Ducted, 2 tons | None | 2 · index — |
| Ducted, 2.5 to 3 tons | None | 2 · index — |
| Ducted, 3.5 to 4.5 tons | None | 2 · index — |
| Non-ducted, up to 1.5 tons | 5 · index 38% | None |
| Non-ducted, 2 tons | 1 · index 42% | None |
| Non-ducted, 2.5 to 3 tons | 1 · index 24% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | A/H EDENCold-climate score, best model | Badger manufactureCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Ducted, 2 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 52.5(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE4 of 5 models qualify · AHRI 217513412 | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | A/H EDENAll-around score, best model | Badger manufactureAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | No models in this size class | None on this board (0 of 2 models have all five ratings) |
| Ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 2 models have all five ratings) |
| Ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 2 models have all five ratings) |
| Non-ducted, up to 1.5 tons | 46.3(50 is the typical model of its size class)AS09HP2ACwith ductless indoor unit AS09HP2AE5 of 5 models have all five ratings · AHRI 217513412 | No models in this size class |
| Non-ducted, 2 tons | 41.6(50 is the typical model of its size class)AS24HP2AC*with ductless indoor unit AS24HP2AE1 of 1 models have all five ratings · AHRI 217617212 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 24.0(50 is the typical model of its size class)AS36HP2AC*with ductless indoor unit AS36HP2AE1 of 1 models have all five ratings · AHRI 217617213 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | A/H EDEN | Badger manufacture |
|---|---|---|
| COP at 5°F | beats 87% · 2.10AS36HP2AC*Non-ducted, 2.5 to 3 tons | — |
| Capacity retention at 5°F | beats 50% · 75%AS12HP1ACNon-ducted, up to 1.5 tons | — |
| HSPF2 | beats 66% · 10.0AS09HP2ACNon-ducted, up to 1.5 tons | beats 27% · 7.5DHP5048E1000BDucted, 3.5 to 4.5 tons |
| SEER2 | beats 50% · 21.0AS24HP2AC*Non-ducted, 2 tons | beats 22% · 14.3DHP5048E1000BDucted, 3.5 to 4.5 tons |
| EER2 | beats 47% · 12.0AS09HP2ACNon-ducted, up to 1.5 tons | beats 69% · 11.7DHP5048E1000BDucted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 73% · 12,500 Btu/hAS18HP2ACNon-ducted, up to 1.5 tons | — |