Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
agtana vs SUPREME heat pumps
Measured against models of the same size and duct type, SUPREME scores higher on 3 of the 6 ratings. agtana has 5 outdoor models, SUPREME has 5 outdoor models. agtana and SUPREME have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- agtana
- SUPREME
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | agtana | SUPREME |
|---|---|---|
| Efficiency index | —median — | 66%median — |
| COP at 5°F | —median — | 24%median 1.80 |
| Capacity retention at 5°F | —median — | 85%median 99% |
| HSPF2 | 4%median 8.2 | 77%median 10.5 |
| SEER2 | 13%median 18.1 | 75%median 23.5 |
| EER2 | 22%median 10.8 | 64%median 12.5 |
| Heating capacity at 5°F | —median — | 80%median 17,800 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 5 | 7 |
Share of models meeting each standard
| Standard | agtana | SUPREME |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 100%5 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 100%5 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 100%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 40%2 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- agtana
- SUPREME
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | agtana | SUPREME |
|---|---|---|
| Non-ducted, up to 1.5 tons | 3 · index — | 4 · index 68% |
| Non-ducted, 2 tons | 1 · index — | 1 · index 56% |
| Non-ducted, 2.5–3 tons | 1 · index — | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | agtanaCold-climate score, best model | SUPREMECold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 73.8(50 is the typical model of its size class)T55-SUPAE18E454with ductless indoor unit T55-SUPAE18I4544 of 4 models qualify · AHRI 217752771 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 58.0(50 is the typical model of its size class)SUP25S24R454-Owith ductless indoor unit SUP25S24R454-I1 of 1 models qualify · AHRI 218828121 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | agtanaAll-around score, best model | SUPREMEAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models have all five ratings) | 74.4(50 is the typical model of its size class)SUP25S12R454-Owith ductless indoor unit SUP25S12R454-I4 of 4 models have all five ratings · AHRI 218828119 |
| Non-ducted, 2 tons | None on this board (0 of 1 models have all five ratings) | 56.1(50 is the typical model of its size class)SUP25S24R454-Owith ductless indoor unit SUP25S24R454-I1 of 1 models have all five ratings · AHRI 218828121 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | agtana | SUPREME |
|---|---|---|
| COP at 5°F | — | beats 48% · 1.92T55-SUPAE18E454Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | — | beats 87% · 100%T55-SUPAE18E454Non-ducted, up to 1.5 tons |
| HSPF2 | beats 4% · 8.2AGAC-12AW1Non-ducted, up to 1.5 tons | beats 85% · 11.0T55-SUPAE18E454Non-ducted, up to 1.5 tons |
| SEER2 | beats 15% · 18.1AGAC-12AW1Non-ducted, up to 1.5 tons | beats 88% · 25.4T55-SUPAE12E454Non-ducted, up to 1.5 tons |
| EER2 | beats 35% · 11.6AGAC-18AW1Non-ducted, up to 1.5 tons | beats 83% · 14.0SUP25S12R454-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | — | beats 93% · 18,000 Btu/hT55-SUPAE18E454Non-ducted, up to 1.5 tons |