Skip to content

SUPREME heat pump efficiency: 5 outdoor models compared

SUPREME has 5 heat pump outdoor models certified with this refrigerant group, in 7 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes SUPREME makes. SUPREME has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
7
Efficiency index
66%
Typical model vs same-size, same-type peers (5 models)
Meet CEE 2025
100%
5 models

How SUPREME compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
SUPREME against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of SUPREME’s own modelsSUPREME is strongest on capacity retention at 5°F (its typical model beats 85% of comparable models) and weakest on COP at 5°F (24%).
  • SUPREME
  • Middle half of its models
  • Other ranked manufacturers
SUPREME

Source: AHRI Directory, NEEP · as of

Average peer percentile of SUPREME’s models
RatingBeats comparable modelsRankRaw median
Efficiency index5 models scored66%Not ranked—
COP at 5°F5 models scored24%Not ranked1.80
Capacity retention at 5°F5 models scored85%Not ranked99%
HSPF25 models scored77%Not ranked10.5
SEER25 models scored75%Not ranked23.5
EER25 models scored64%Not ranked12.5
Heating capacity at 5°F5 models scored80%Not ranked17,800 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
SUPREME’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • SUPREME (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons468%26%78%76%
Non-ducted, 2 tons156%17%70%70%

Every SUPREME model in the market

SUPREME’s 5 models with a known size and duct type, over the shape of the whole catalog.
SUPREME models by size and ratingColoured: SUPREME · grey shapes: all 14,508 models · lines: catalog medians by size
  • SUPREME models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 supreme models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top SUPREME models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 SUPREME cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1T55-SUPAE18E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE18I4541.5 tons18,000 Btu/h · Non-ducted100%1.9211.018,00021.4CEE 25CEE 26XcelES CC2217752771Non-ducted, up to 1.5 tons73.8
2SUP25S12R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S12R454-I1 ton12,000 Btu/h · Non-ducted100%1.8010.512,00025.0CEE 25CEE 26Xcel1218828119Non-ducted, up to 1.5 tons62.1
3T55-SUPAE12E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE12I4541 ton12,000 Btu/h · Non-ducted96%1.8010.511,50025.4CEE 25CEE 26XcelES CC2217752770Non-ducted, up to 1.5 tons60.0
4SUP25S24R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S24R454-I2 tons24,000 Btu/h · Non-ducted93%1.8010.022,40022.5CEE 25CEE 26Xcel1218828121Non-ducted, 2 tons58.0
5SUP25S18R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S18R454-I1.5 tons18,000 Btu/h · Non-ducted99%1.8010.017,80023.5CEE 25CEE 26Xcel1218828120Non-ducted, up to 1.5 tons55.8

All-around best

Top 5 SUPREME models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1SUP25S12R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S12R454-I1 ton12,000 Btu/h · Non-ducted100%1.8010.525.014.0CEE 25CEE 26Xcel1218828119Non-ducted, up to 1.5 tons74.462.186.762.1
2T55-SUPAE12E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE12I4541 ton12,000 Btu/h · Non-ducted96%1.8010.525.413.4CEE 25CEE 26XcelES CC2217752770Non-ducted, up to 1.5 tons72.960.085.960.0
3T55-SUPAE18E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE18I4541.5 tons18,000 Btu/h · Non-ducted100%1.9211.021.412.5CEE 25CEE 26XcelES CC2217752771Non-ducted, up to 1.5 tons64.073.854.373.8
4SUP25S18R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S18R454-I1.5 tons18,000 Btu/h · Non-ducted99%1.8010.023.512.5CEE 25CEE 26Xcel1218828120Non-ducted, up to 1.5 tons61.255.866.555.8
5SUP25S24R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S24R454-I2 tons24,000 Btu/h · Non-ducted93%1.8010.022.511.7CEE 25CEE 26Xcel1218828121Non-ducted, 2 tons56.158.054.258.0

Best model on each rating

SUPREME’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FT55-SUPAE18E4541.92Non-ducted, up to 1.5 tons48%217752771
Capacity retention at 5°FT55-SUPAE18E454100%Non-ducted, up to 1.5 tons87%217752771
HSPF2T55-SUPAE18E45411.0Non-ducted, up to 1.5 tons85%217752771
SEER2T55-SUPAE12E45425.4Non-ducted, up to 1.5 tons88%217752770
EER2SUP25S12R454-O14.0Non-ducted, up to 1.5 tons83%218828119
Heating capacity at 5°FT55-SUPAE18E45418,000 Btu/hNon-ducted, up to 1.5 tons93%217752771

All 5 SUPREME models in Explore

SUPREME size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
SUPREME: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons73.8(50 is the typical model of its size class)T55-SUPAE18E454with ductless indoor unit T55-SUPAE18I4544 of 4 models qualify · AHRI 21775277174.4(50 is the typical model of its size class)SUP25S12R454-Owith ductless indoor unit SUP25S12R454-I4 of 4 models have all five ratings · AHRI 218828119
Non-ducted, 2 tons58.0(50 is the typical model of its size class)SUP25S24R454-Owith ductless indoor unit SUP25S24R454-I1 of 1 models qualify · AHRI 21882812156.1(50 is the typical model of its size class)SUP25S24R454-Owith ductless indoor unit SUP25S24R454-I1 of 1 models have all five ratings · AHRI 218828121

All-around board, every manufacturer

Newest SUPREME certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified SUPREME outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
SUP25S24R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S24R454-I2 tons24,000 Btu/h · Non-ducted1.8093%10.022.5CEE 25CEE 26Xcel1218828121
SUP25S18R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S18R454-I1.5 tons18,000 Btu/h · Non-ducted1.8099%10.023.5CEE 25CEE 26Xcel1218828120
SUP25S12R454-OSUPREME · Builder Serieswith ductless indoor unit SUP25S12R454-I1 ton12,000 Btu/h · Non-ducted1.80100%10.525.0CEE 25CEE 26Xcel1218828119
T55-SUPAE18E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE18I4541.5 tons18,000 Btu/h · Non-ducted1.92100%11.021.4CEE 25CEE 26XcelES CC2217754306
T55-SUPAE12E454SUPREME · T55 Serieswith ductless indoor unit T55-SUPAE12I4541 ton12,000 Btu/h · Non-ducted1.8096%10.525.4CEE 25CEE 26XcelES CC2217754305

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare SUPREME

Manufacturers of a similar size, side by side.

SUPREME includes these brand names as listed in AHRI: SUPREME. Standards are checked against published thresholds; program rules beyond ratings are not checked.