Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Clima Smart vs DEMULLER heat pumps
Measured against models of the same size and duct type, Clima Smart scores higher on 6 of the 6 ratings. Clima Smart has 8 outdoor models, DEMULLER has 8 outdoor models. Clima Smart and DEMULLER have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Clima Smart
- DEMULLER
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Clima Smart | DEMULLER |
|---|---|---|
| Efficiency index | 73% (higher)median — | 28% (higher)median — |
| COP at 5°F | 35% (higher)median 1.90 | 21% (higher)median 1.81 |
| Capacity retention at 5°F | 79% (higher)median 98% | 40% (higher)median 73% |
| HSPF2 | 68% (higher)median 10.0 | 15% (higher)median 8.3 |
| SEER2 | 89% (higher)median 25.0 | 33% (higher)median 19.5 |
| EER2 | 80% (higher)median 13.8 | 29% (higher)median 11.1 |
| Heating capacity at 5°F | 71% (higher)median 21,100 Btu/h | 23% (higher)median 7,700 Btu/h |
| Outdoor models | 8 | 8 |
| AHRI certifications | 10 | 8 |
Share of models meeting each standard
| Standard | Clima Smart | DEMULLER |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%8 models | 50%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%8 models | 50%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%8 models | 75%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 100%8 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Clima Smart
- DEMULLER
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Clima Smart | DEMULLER |
|---|---|---|
| Non-ducted, up to 1.5 tons | 4 · index 74% | 8 · index 28% |
| Non-ducted, 2 tons | 1 · index 56% | None |
| Non-ducted, 2.5–3 tons | 2 · index 80% | None |
| Non-ducted, 3.5–4.5 tons | 1 · index 70% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Clima SmartCold-climate score, best model | DEMULLERCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 70.9(50 is the typical model of its size class) (higher)MU-CSU18HEI2NAM0T24-3PO4 of 4 models qualify · AHRI 218044807 | 47.6(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH26 of 8 models qualify · AHRI 216623860 |
| Non-ducted, 2 tons | 58.0(50 is the typical model of its size class)CSU24HEI2NAK0T24with ductless indoor unit CSU24HEI2NAK0T241 of 1 models qualify · AHRI 218043761 | No models in this size class |
| Non-ducted, 2.5–3 tons | 68.0(50 is the typical model of its size class)MU-CSU27HEI2NAM0T24-4PO2 of 2 models qualify · AHRI 218044808 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 48.1(50 is the typical model of its size class)MU-CSU48HEI2NAM0T24-6PO1 of 1 models qualify · AHRI 218044810 | No models in this size class |
All-around best
| Size and duct type | Clima SmartAll-around score, best model | DEMULLERAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 82.6(50 is the typical model of its size class) (higher)MU-CSU18HEI2NAM0T24-3PO4 of 4 models have all five ratings · AHRI 218044807 | 49.3(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH28 of 8 models have all five ratings · AHRI 216623860 |
| Non-ducted, 2 tons | 56.1(50 is the typical model of its size class)CSU24HEI2NAK0T24with ductless indoor unit CSU24HEI2NAK0T241 of 1 models have all five ratings · AHRI 218043761 | No models in this size class |
| Non-ducted, 2.5–3 tons | 83.1(50 is the typical model of its size class)MU-CSU27HEI2NAM0T24-4PO2 of 2 models have all five ratings · AHRI 218044808 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 70.2(50 is the typical model of its size class)MU-CSU48HEI2NAM0T24-6PO1 of 1 models have all five ratings · AHRI 218044810 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Clima Smart | DEMULLER |
|---|---|---|
| COP at 5°F | beats 63% · 2.00MU-CSU18HEI2NAM0T24-3PONon-ducted, up to 1.5 tons | beats 42% · 1.90DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 90% · 101%CSU09HEI2NAM0T24Non-ducted, up to 1.5 tons | beats 71% · 89%DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| HSPF2 | beats 80% · 10.5MU-CSU27HEI2NAM0T24-4PONon-ducted, 2.5–3 tons | beats 29% · 9.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| SEER2 | beats 99% · 26.5MU-CSU27HEI2NAM0T24-4PONon-ducted, 2.5–3 tons | beats 56% · 22.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| EER2 | beats 97% · 14.0MU-CSU27HEI2NAM0T24-4PONon-ducted, 2.5–3 tons | beats 44% · 12.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 98% · 19,800 Btu/hMU-CSU18HEI2NAM0T24-3PONon-ducted, up to 1.5 tons | beats 34% · 8,400 Btu/hDMLHT1W-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2Non-ducted, up to 1.5 tons |