- Insights
- Manufacturers
- DEMULLER
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DEMULLER heat pump efficiency: 8 outdoor models compared
DEMULLER has 8 heat pump outdoor models certified with this refrigerant group, in 8 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DEMULLER makes. DEMULLER has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 8
- AHRI certifications
- 8
- Efficiency index
- 28%
- Typical model vs same-size, same-type peers (8 models)
- Meet CEE 2025
- 50%
- 4 models
How DEMULLER compares with comparable models
- DEMULLER
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index8 models scored | 28% | Not ranked | — |
| COP at 5°F8 models scored | 21% | Not ranked | 1.81 |
| Capacity retention at 5°F8 models scored | 40% | Not ranked | 73% |
| HSPF28 models scored | 15% | Not ranked | 8.3 |
| SEER28 models scored | 33% | Not ranked | 19.5 |
| EER28 models scored | 29% | Not ranked | 11.1 |
| Heating capacity at 5°F8 models scored | 23% | Not ranked | 7,700 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 50% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75% | 6 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- DEMULLER (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 8 | 28% | 21% | 15% | 33% |
Every DEMULLER model in the market
- DEMULLER models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top DEMULLER models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DMLHT1W-09R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 1 ton9,000 Btu/h · Non-ducted | 89% | 1.90 | 9.0 | 8,000 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623860 | Non-ducted, up to 1.5 tons | 47.6 |
| 2DMLHT1W-12R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.86 | 9.0 | 8,400 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623862 | Non-ducted, up to 1.5 tons | 29.6 |
| 3DMLHT1W-09R4CBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH1 | 1 ton9,000 Btu/h · Non-ducted | 78% | 1.75 | 7.5 | 7,000 | 17.0 | Xcel | 1 | 216623856 | Non-ducted, up to 1.5 tons | 20.8 |
| 4DMLHT1W-09R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4BBPH1 | 1 ton9,000 Btu/h · Non-ducted | 76% | 1.75 | 7.5 | 6,800 | 17.0 | Xcel | 1 | 216623857 | Non-ducted, up to 1.5 tons | 18.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DMLHT1W-09R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 1 ton9,000 Btu/h · Non-ducted | 89% | 1.90 | 9.0 | 22.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 216623860 | Non-ducted, up to 1.5 tons | 49.3 | 47.6 | 51.0 | 47.6 |
| 2DMLHT1W-12R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.86 | 9.0 | 22.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 216623862 | Non-ducted, up to 1.5 tons | 40.3 | 29.6 | 51.0 | 29.6 |
| 3DMLHT1W-09R4CBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH1 | 1 ton9,000 Btu/h · Non-ducted | 78% | 1.75 | 7.5 | 17.0 | 10.2 | Xcel | 1 | 216623856 | Non-ducted, up to 1.5 tons | 16.9 | 20.8 | 13.0 | 20.8 |
| 4DMLHT1W-09R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4BBPH1 | 1 ton9,000 Btu/h · Non-ducted | 76% | 1.75 | 7.5 | 17.0 | 10.2 | Xcel | 1 | 216623857 | Non-ducted, up to 1.5 tons | 15.6 | 18.2 | 13.0 | 18.2 |
| 5DMLHT1W-12R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-12R4BBPH1 | 1 ton12,000 Btu/h · Non-ducted | 62% | 1.70 | 7.5 | 17.0 | 9.8 | None | 1 | 216623859 | Non-ducted, up to 1.5 tons | 7.4 | 4.2 | 10.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 1.90 | Non-ducted, up to 1.5 tons | 42% | 216623860 |
| Capacity retention at 5°F | DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 89% | Non-ducted, up to 1.5 tons | 71% | 216623860 |
| HSPF2 | DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 9.0 | Non-ducted, up to 1.5 tons | 29% | 216623860 |
| SEER2 | DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 22.0 | Non-ducted, up to 1.5 tons | 56% | 216623860 |
| EER2 | DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2 | 12.0 | Non-ducted, up to 1.5 tons | 44% | 216623860 |
| Heating capacity at 5°F | DMLHT1W-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2 | 8,400 Btu/h | Non-ducted, up to 1.5 tons | 34% | 216623862 |
DEMULLER size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 47.6(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH26 of 8 models qualify · AHRI 216623860 | 49.3(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH28 of 8 models have all five ratings · AHRI 216623860 |
Newest DEMULLER certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| DMLHT1W-12R4BBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4BBPH2 | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 70% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623863 |
| DMLHT1W-12R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4CBPH2 | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 70% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623862 |
| DMLHT1W-09R4BBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4BBPH2 | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 89% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623861 |
| DMLHT1W-09R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH2 | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 89% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 216623860 |
| DMLHT1W-12R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-12R4BBPH1 | 1 ton12,000 Btu/h · Non-ducted | 1.70 | 62% | 7.5 | 17.0 | None | 1 | 216623859 |
Compare DEMULLER
DEMULLER includes these brand names as listed in AHRI: DEMULLER. Standards are checked against published thresholds; program rules beyond ratings are not checked.