Both views use the same certified data. This device remembers your choice.
Brothers vs DEMULLER heat pumps
Measured against models of the same size and duct type, Brothers scores higher on 2 of the 6 ratings. Brothers has 8 outdoor models, DEMULLER has 8 outdoor models. Brothers and DEMULLER have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Brothers
- DEMULLER
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Brothers | DEMULLER |
|---|---|---|
| Efficiency index | —median — | 30%median — |
| COP at 5°F | —median — | 22%median 1.81 |
| Capacity retention at 5°F | —median — | 42%median 73% |
| HSPF2 | 22% (higher)median 7.5 | 16% (higher)median 8.3 |
| SEER2 | 19%median 14.3 | 34%median 19.5 |
| EER2 | 57% (higher)median 11.7 | 32% (higher)median 11.1 |
| Heating capacity at 5°F | —median — | 24%median 7,700 Btu/h |
| Outdoor models | 8 | 8 |
| AHRI certifications | 18 | 8 |
Share of models meeting each standard
| Standard | Brothers | DEMULLER |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 50%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 50%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 75%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Brothers
- DEMULLER
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Brothers | DEMULLER |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index — | None |
| Ducted, 2 tons | 3 · index — | None |
| Ducted, 2.5 to 3 tons | 3 · index — | None |
| Non-ducted, up to 1.5 tons | None | 8 · index 30% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BrothersCold-climate score, best model | DEMULLERCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 3 models qualify) | No models in this size class |
| Ducted, 2.5 to 3 tons | None on this board (0 of 3 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 49.3(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH26 of 8 models qualify · AHRI 216623860 |
All-around best
| Size and duct type | BrothersAll-around score, best model | DEMULLERAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models have all five ratings) | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 3 models have all five ratings) | No models in this size class |
| Ducted, 2.5 to 3 tons | None on this board (0 of 3 models have all five ratings) | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 51.6(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH28 of 8 models have all five ratings · AHRI 216623860 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Brothers | DEMULLER |
|---|---|---|
| COP at 5°F | — | beats 44% · 1.90DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | — | beats 73% · 89%DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| HSPF2 | beats 26% · 7.5BRO-36HN7Ducted, 2.5 to 3 tons | beats 30% · 9.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| SEER2 | beats 22% · 14.3BRO-18HN7Ducted, up to 1.5 tons | beats 59% · 22.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| EER2 | beats 59% · 11.7BRO-36HN7Ducted, 2.5 to 3 tons | beats 47% · 12.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | — | beats 36% · 8,400 Btu/hDMLHT1W-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2Non-ducted, up to 1.5 tons |